| MRC |
Requirement Statement |
Reply Statement |
| ABHP |
OVERALL LENGTH |
20.313 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
12.500 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
10.000 INCHES NOMINAL |
| ACDC |
CURRENT TYPE |
AC |
| ACZB |
FREQUENCY RATING |
0.05 KILOHERTZ MINIMUM AND 1.00 KILOHERTZ MAXIMUM |
| AKYD |
ACCESSORY COMPONENTS AND QUANTITY |
CASE ACCESSORIES CY-1456/USM-25A; LEAD,TEST CG - 1099/USM-25A; PROD,TEST MX-1537/AP; PROD,TEST MX-1538/AP; CABLE ASSEMBLY,POWER,ELECTRICAL CX-2454/U/6FT 0 IN.; RF CABLE ASSEMBLY CG-530/U/3 FT 1 IN.; MOUNTING MT-1292/USM-25B |
| AMSE |
VOLTAGE RATING |
103.5 VOLTS MINIMUM AND 126.5 VOLTS MAXIMUM |
| ATES |
BEAM QUANTITY |
1 |
| AXGY |
MOUNTING METHOD |
CHASSIS |
| BGQK |
SCREEN SIZE |
3 IN. |
| BGQL |
SWEEP CIRCUITS |
INCLUDED |
| BGQM |
GENERATOR DRIVEN FEATURE |
NOT INCLUDED |
| BGQP |
SWEEP FREQUENCY RANGE |
80.000 TO 200000.000 HERTZ |
| BGQQ |
SINGLE TRIGGER SWEEP DURATION |
1.2 MICROSECONDS MINIMUM AND 12000.0 MICROSECONDS MAXIMUM |
| BGRZ |
TRIGGER SWEEP VOLTAGE AMPLITUDE RATING |
5.0 VOLTS NOMINAL |
| BGSB |
TRIGGER SWEEP POLARITY SWITCH |
INCLUDED |
| BGSC |
TRIGGER SWEEP MARKER INTERVALS |
10 USEC ON 2000 YD; 50 USEC ON 10000 RADAR YDS |
| BGSD |
EXPANDED SWEEP |
NOT PROVIDED |
| BHDD |
AMPLIFIER DEFLECTION SENSITIVITY PROVISION |
PROVIDED |
| BHDF |
VERTICAL DEFLECTION SENSITIVITY VOLTAGE RATING |
0.5 VOLTS NOMINAL RMS PER INCH |
| BHDH |
INPUT INTENSITY MODULATION FEATURE |
NOT PROVIDED |
| BHDL |
PLATE DIRECT CONNECTION DEFLECTION SENSITIVITY PROVISION |
PROVIDED |
| BHDM |
DIRECT CONNECTION VERTICAL DEFLECTION SENSITIVITY VOLTAGE RATING |
19.0 VOLTS NOMINAL RMS PER INCH |
| BHDP |
FREQUENCY RESPONSE RATING |
PROVIDED |
| BHDR |
Y-AXIS FREQUENCY RESPONSE RATING |
50.0 HERTZ MINIMUM AND 8000000.0 HERTZ MAXIMUM |
| BHDS |
Z-AXIS FREQUENCY RESPONSE RATING |
50.0 HERTZ MINIMUM AND 8000000.0 HERTZ MAXIMUM |
| BHDT |
AMPLIFIER INPUT IMPEDANCE RATING PROVISION |
PROVIDED |
| BHDY |
Z-AXIS INPUT IMPEDANCE RATING |
1.0 MEGOHMS NOMINAL |
| BHFF |
CALIBRATED SCREEN SCALE |
NOT INCLUDED |
| BHFH |
TRACE STORAGE TUBE |
NOT INCLUDED |
| BHFT |
CAMERA RECORDING DEVICE ACCOMMODATION |
NOT PROVIDED |
| FAAZ |
PHASE |
SINGLE |
| FEAT |
SPECIAL FEATURES |
Y-AXIS INPUT IMPEDANCE RATING 1 MEG PORM 5 PCT SHUNTED W/26 UUF PORM 2 UUF |