| MRC |
Requirement Statement |
Reply Statement |
| AAQL |
BODY STYLE |
26B W/O MTG FACILITIES, AXIAL TERMINALS |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABJT |
TERMINAL LENGTH |
0.187 INCHES NOMINAL |
| ABPM |
BODY DIAMETER |
0.688 INCHES MINIMUM AND 0.812 INCHES MAXIMUM |
| ADAQ |
BODY LENGTH |
0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM |
| AEBJ |
CONTINUOUS CURRENT RATING IN AMPS |
7.0 |
| AEBT |
TERMINAL DIAMETER |
0.138 INCHES NOMINAL |
| AEBZ |
SCHEMATIC DIAGRAM DESIGNATOR |
1C NO COMMON OR GROUNDED ELECTRODE(S) |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNIFIED NATIONAL COARSE (UNC) |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED MOUNTING HOLES |
| CQBQ |
CAPACITANCE VALUE PER SECTION |
25.000 PICOFARADS SINGLE SECTION |
| CQJJ |
NONDERATED OPERATING TEMP |
-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
| CQLZ |
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS |
0.0 SINGLE SECTION |
| CQWM |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION |
7500.0 DC SINGLE SECTION |
| CRHD |
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS |
-30.0 TO 30.0 SINGLE SECTION |
| CRTP |
TOLERANCE RANGE PER SECTION |
-10.00 TO 10.00 PERCENT SINGLE SECTION |
| CWPK |
INSULATION RESISTANCE AT REFERENCE TEMP |
10000.0 MEGOHMS |
| CWPM |
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT |
0.100 |
| CWSG |
TERMINAL SURFACE TREATMENT |
SILVER |
| PMLC |
PRECIOUS MATERIAL AND LOCATION |
TERMINAL SURFACES SILVER |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 THREADED HOLE |