National Stock Number(NSN): 6685-01-263-0417 (6685012630417, 012630417)
| NIIN: |
01-263-0417 |
Item Name: |
SENSOR,AIR UNDERCOO |
INC: |
77777 |
| FSC: |
6685
|
Assignment Date: |
Sep-09-1987 |
CRIT: |
H |
IIG: |
77777 |
| ISC: |
5 |
Date Standardized: |
Sep-09-1987 |
HMIC: |
P |
DODIC: |
|
| NSC: |
0 |
Cancellation Date: |
|
PMIC: |
A |
FIIG: |
A23900 |
| ESD: |
B |
Schedule B: |
|
DEMIL: |
Q |
DEMIL INT: |
3 |
| TIIC: |
4 |
Originator: |
97 |
ADPEC: |
0 |
RPDMRC: |
1 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
00123-0400-2A |
60678
|
ROSEMOUNT AEROSPACE INC. |
C |
5 |
9 |
5 |
MF |
|
B |
|
|
|
|
|
123DJ2 |
60678
|
ROSEMOUNT AEROSPACE INC. |
C |
5 |
9 |
5 |
MF |
|
B |
|
|
|
|
|
123DJ2C |
60678
|
ROSEMOUNT AEROSPACE INC. |
C |
3 |
2 |
5 |
MF |
|
|
|
|
|
|
|
DAA3287P006-103 |
1W025
|
NORTHROP GRUMMAN SYSTEMS CORP |
C |
5 |
9 |
5 |
MF |
|
B |
|
|
|
|
|
DAA3287P006-109 |
1W025
|
NORTHROP GRUMMAN SYSTEMS CORP |
C |
7 |
2 |
1 |
MF |
|
D |
|
|
|
|
|
DAA3287P006-109 |
76823
|
NORTHROP GRUMMAN SYSTEMS CORPORATION |
H |
7 |
2 |
|
|
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DF |
F59 |
D |
|
0 |
U |
1 |
D |
$77,705.00 |
EA |
|
------- |
Jun-01-2019 |
H |
| DF |
F59 |
D |
N |
0 |
U |
1 |
F |
$77,705.00 |
EA |
|
--SBQ-P |
Nov-01-2023 |
C |
| DF |
F59 |
D |
|
0 |
U |
1 |
I |
$77,705.00 |
EA |
|
------- |
Nov-01-2023 |
C |
| DS |
SMS |
Z |
N |
0 |
U |
1 |
D |
$29,868.75 |
EA |
|
------- |
Oct-01-2010 |
H |
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| AGAV |
END ITEM IDENTIFICATION |
PACER SPECIAL |
| FEAT |
SPECIAL FEATURES |
SENSOR CHECKS THAT COOLING FLOW AND/OR COOLING TEMPERATURE IS ABOVE FOLLOWING CURVE,25 DEG F AT 4 LB/MIN TO 80 DEG F AT 7.5 TO 8.0 LB/MIN;NORMAL OPERATING RANGE 25 TO 80 DEG F;WHEN THE COOLING FLOW AND/OR COOLING TEMP FALLS BELOW THE CURVE THE SENSOR WILL DETECT INSUFFICIENT COOLING AND SWITCH FROM N.O. TO N.C SWITCH SPDT 2A MIN RATING;8 PIN CONNECTOR;SWITCHING,PINS 3 TO 4 NORMALLY CLOSED;4-5 NORMALLY OPEN; OPERATING VOLTAGE 28 VDC |
| NHCF |
NUCLEAR HARDNESS CRITICAL FEATURE |
HARDENED |
| TEXT |
GENERAL CHARACTERISTICS ITEM DESCRIPTION |
TO BE USED IN 3.0 INCH DIA. DUCT;WEIGHT 0.75 LBS;SENSOR INCORPORATES AN OUTPUT DELAY OF 140 POM 15 SECONDS;ENVIRONMENT MINUS 65 DEGREES TO 190 DEG F,1.0 TO 15.5 PSIA;ACCURACY 5% FULL SCALE;END FITTING PER MS33514E4;RECEPTACLE TO MATE WITH D38999/26WC8S CONNECTOR KEYING D;PROBE LENGTH 3.51 INCHES POM 0.04 INCH |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| FNN5 |
FXGG |
Jun-01-2011 |
3 |
H |
B |
|
TN|TU |
TN|TU |
| Description: |
VALVES THEMOSTATIC NOI/THEMOSTATS |
Originating Activity: |
SX |
| Hazardous Material: |
|
National Motor Freight Classification Number: |
188340 |
| Less Than One Truckload: |
J |
NMFC Sub-Item: |
X |
| Uniform Freight Classification Number: |
33230 |
Rail Variance Code: |
|
| Less Than One Carload: |
J |
Water Commodity Code: |
653 |
| Type of Cargo Code: |
Z |
Special Handling Code: |
Z |
| Air Commodity Special Handling Code: |
AZ |
Air Dimension Code: |
A |
| Source: |
P |
Primary Inventory Control Activity (PICA) |
Status: |
C |
| Pri/Sec ICC: |
P |
Container NSN: |
|
Category Code: |
60ZZ |
| Lvl A Pkg Req: |
E |
Unit Pack Size: |
|
Pres Material: |
XX |
| Lvl B Pkg Req: |
Q |
Unit Pack Weight: |
1.2 |
Pres Method: |
10 |
| Lvl C Pkg Req: |
|
Unit Pack Cube: |
0.350 |
Wrapping Mat: |
XX |
| Opt Proc Ind: |
O |
Unpkg Item Dims: |
|
Spec Marking: |
05 |
| Container FSC: |
|
SPI Number: |
|
SPI Revision: |
|
| Unpkg Weight: |
|
SPI Date: |
|
Pkg Design Activity: |
13873
|
| Inter Container Qty: |
AAA |
Inter Container Code: |
E5 |
Clean/Dry Procedure: |
1 |
| Unit Container: |
D3 |
Item Type Storage: |
|
Unit Container Level: |
|
| |
|
Cush/Dun Material: |
XX |
Cush/Dun Thickness: |
X |
|