National Stock Number(NSN): 6680-00-461-9714 (6680004619714, 004619714)
| NIIN: |
00-461-9714 |
Item Name: |
TACHOMETER,MECHANICAL,HANDHELD |
INC: |
07114
|
| FSC: |
6680
|
Assignment Date: |
Feb-23-1972 |
CRIT: |
N |
IIG: |
07114 |
| ISC: |
6 |
Date Standardized: |
May-24-1973 |
HMIC: |
N |
DODIC: |
|
| NSC: |
8 |
Cancellation Date: |
Dec-19-2000 |
PMIC: |
A |
FIIG: |
T145-E |
| ESD: |
|
Schedule B: |
|
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
4 |
Originator: |
CX |
ADPEC: |
|
RPDMRC: |
3 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
2304S |
57737
|
HERMAN H STICHT COMPANY, INC |
H |
3 |
2 |
4 |
SB |
4 |
D |
|
|
|
|
|
9911 |
07239
|
AVO INTL |
H |
3 |
2 |
4 |
SB |
4 |
D |
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DF |
JCD |
Y |
U |
0 |
U |
1 |
L |
$99.73 |
EA |
|
--LVE-N |
Dec-01-1995 |
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DF |
N |
DISPOSAL |
000 |
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| AFJU |
CARRYING CASE |
PROVIDED |
| AGAV |
END ITEM IDENTIFICATION |
DICTATRONE TIME ANNOUNCER,MODEL NO. DCTA-M1 |
| AKYD |
ACCESSORY COMPONENTS AND QUANTITY |
1 LARGE POINTED RUBBER TIP;1 LARGE HOLLOW RUBBER TIP;1 RUBBER LINED FUNNEL TIP;1 SMALL POINTED RUBBER TIP;1 TRIANGULAR STEEL TIP;1 3.5 IN. EXTENSION BAR;1 6.0 IN. CIRCUMFERENCE WHEEL TIP FOR FPM MEASUREMENT |
| ANBG |
OPERATING RANGE |
0.0 TO 100.0 FEET PER MINUTE AND 0.0 TO 200.0 REVOLUTIONS PER MINUTE |
| ANSX |
MEASUREMENT UNIT |
FEET PER MINUTE AND REVOLUTIONS PER MINUTE |
| ANSZ |
SCALE MEASUREMENT RANGE |
0.0 TO 10.0 AND 0.0 TO 100.0 |
| APSJ |
SCALE QUANTITY |
2 |
| ASPC |
POINTER QUANTITY |
2 |
| AWAG |
SCALE SMALLEST INCREMENT |
10.0 FEET PER MINUTE AND 0.1 REVOLUTIONS PER MINUTE |
| BGPK |
SPEED SELECTOR |
NOT PROVIDED |
| BGPL |
MANUAL RESET |
PROVIDED |
| BGPQ |
SCALE MEASUREMENT UNIT |
FEET PER MINUTE AND REVOLUTIONS PER MINUTE |
| FEAT |
SPECIAL FEATURES |
TIMING PERIOD 6 SECONDS;WHEN FPM MEASUREMENTS ARE MADE DIVIDE READINGS BY 2 |
|