National Stock Number(NSN): 6640-01-069-6322 (6640010696322, 010696322)
| NIIN: |
01-069-6322 |
Item Name: |
OVEN,LABORATORY |
INC: |
17096
|
| FSC: |
6640
|
Assignment Date: |
Dec-20-1978 |
CRIT: |
X |
IIG: |
17096 |
| ISC: |
2 |
Date Standardized: |
Mar-30-1987 |
HMIC: |
P |
DODIC: |
|
| NSC: |
4 |
Cancellation Date: |
Aug-31-2022 |
PMIC: |
U |
FIIG: |
T269-E |
| ESD: |
|
Schedule B: |
8514.10.0000 |
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
1 |
Originator: |
AC |
ADPEC: |
|
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
430 |
92284
|
NATIONAL APPLIANCE CO SUB OF HEINICKE INSTRUMENTS CO |
H |
3 |
9 |
4 |
51 |
4 |
D |
|
|
|
|
|
N8530-3 |
22353
|
BAXTER HEALTHCARE CORP BAXTER SCIENTIFIC PRODUCTS DIV GOVERNMENT SALES |
H |
5 |
9 |
4 |
51 |
4 |
B |
|
|
|
|
|
S-64127C |
64484
|
SARGENT-WELCH SCIENTIFIC CO |
H |
5 |
2 |
4 |
51 |
4 |
D |
|
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ACDC |
CURRENT TYPE |
AC |
| ACZB |
FREQUENCY RATING |
50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| ADJT |
INSIDE WIDTH |
41.250 INCHES NOMINAL |
| ADJV |
OUTSIDE WIDTH |
46.250 INCHES NOMINAL |
| AFEF |
INSIDE DEPTH |
17.500 INCHES NOMINAL |
| AFMQ |
INSIDE HEIGHT |
24.000 INCHES NOMINAL |
| AFMW |
OUTSIDE HEIGHT |
36.000 INCHES NOMINAL |
| AKYD |
ACCESSORY COMPONENTS AND QUANTITY |
THERMOMETER 1 |
| AMSE |
VOLTAGE RATING |
230.0 VOLTS NOMINAL |
| ANPT |
POWER RATING |
2.8 KILOWATTS NOMINAL |
| AQZF |
CONTROL TYPE |
LINE SWITCH AND PILOT LIGHT AND TEMPERATURE CONTROL DIAL AND THERMOMETER |
| ASQJ |
OPERATING TEMP RANGE IN DEG CELSIUS |
22.0 TO 200.0 |
| AZZH |
HEAT SOURCE FOR WHICH DESIGNED |
INTEGRAL |
| BCXB |
OUTSIDE DEPTH |
23.000 INCHES NOMINAL |
| BDWT |
HEATING METHOD |
ELECTRICAL |
| BGXH |
WATER JACKET |
NOT PROVIDED |
| BGZL |
SHELF QUANTITY |
2 |
| BGZM |
SHELF ADJUSTABILITY |
ADJUSTABLE |
| BHGT |
CIRCULATION METHOD |
GRAVITY |
| BLST |
INSULATED CABINET |
PROVIDED |
| BNDW |
COOLING COILS FOR BELOW ROOM TEMP USE |
NOT INCLUDED |
| BPYK |
SHELF MATERIAL |
METAL |
| BQMH |
CABINET OUTER WALL MATERIAL |
STEEL |
| BQMJ |
CABINET INNER WALL MATERIAL |
STEEL, STAINLESS |
| BQMN |
OUTER DOOR QUANTITY |
2 |
| BQMR |
OUTER DOOR INSULATION FEATURE |
INCLUDED |
| BQWH |
MATERIAL CHARACTERISTIC |
PERFORATED |
| BQWN |
VACUUM CHAMBER |
NOT INCLUDED |
| FAAZ |
PHASE |
SINGLE |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| G510 |
|
Apr-01-1991 |
0 |
0 |
|
|
75 |