National Stock Number(NSN): 6636-00-013-8808 (6636000138808, 000138808)
| NIIN: |
00-013-8808 |
Item Name: |
CHAMBER,ENVIRONMENTAL TESTING |
INC: |
39657
|
| FSC: |
6636
|
Assignment Date: |
May-03-1968 |
CRIT: |
X |
IIG: |
39657 |
| ISC: |
6 |
Date Standardized: |
Jun-14-1971 |
HMIC: |
N |
DODIC: |
|
| NSC: |
0 |
Cancellation Date: |
|
PMIC: |
A |
FIIG: |
T269-E |
| ESD: |
|
Schedule B: |
|
DEMIL: |
A |
DEMIL INT: |
1 |
| TIIC: |
1 |
Originator: |
GP |
ADPEC: |
0 |
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
18903050000 |
89944
|
ELBITAMERICA, INC. |
C |
3 |
2 |
2 |
SB |
3 |
B |
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DF |
FHZ |
V |
S |
0 |
U |
1 |
L |
$60,770.00 |
EA |
|
--ANT-V |
Oct-01-2019 |
C |
| DN |
N32 |
J |
X |
0 |
U |
1 |
N |
$4,500.00 |
EA |
|
6RAZBS- |
Feb-01-1984 |
H |
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ABFY |
OVERALL DEPTH |
48.000 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
75.000 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
48.000 INCHES NOMINAL |
| ACDC |
CURRENT TYPE |
AC |
| ACZB |
FREQUENCY RATING |
55.0 HERTZ MINIMUM AND 65.0 HERTZ MAXIMUM |
| ADJT |
INSIDE WIDTH |
28.000 INCHES NOMINAL |
| AFEF |
INSIDE DEPTH |
26.000 INCHES NOMINAL |
| AFGA |
OPERATING TEMP RANGE |
-73.3 TO 121.0 CELSIUS |
| AFMQ |
INSIDE HEIGHT |
30.000 INCHES NOMINAL |
| AFPM |
ASSEMBLY FORM |
ASSEMBLED |
| AFPP |
CLOSURE METHOD |
HINGED COVER |
| AFPV |
COMPARTMENT QUANTITY |
1 |
| AGAV |
END ITEM IDENTIFICATION |
CHAMBER, ENVIRONMENTAL TESTING; TESTS ALTIMETERS AAU ALTITUDE TRANSDUCERS CPU-46A |
| AMSE |
VOLTAGE RATING |
220.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM |
| ANPT |
POWER RATING |
350.0 WATTS MINIMUM AND 1000.0 WATTS MAXIMUM |
| AQZF |
CONTROL TYPE |
TOGGLE SWITCH AND SELECTOR SWITCH AND BLEEDER VALVE AND VACUUM GAGE |
| ARQT |
OPENING LOCATION |
LEFT SIDE OR RIGHT SIDE |
| AZZH |
HEAT SOURCE FOR WHICH DESIGNED |
INTEGRAL |
| BDWT |
HEATING METHOD |
ELECTRICAL |
| BHGT |
CIRCULATION METHOD |
MECHANICAL |
| BHJQ |
DOOR |
PROVIDED |
| BNDW |
COOLING COILS FOR BELOW ROOM TEMP USE |
INCLUDED |
| BQMN |
OUTER DOOR QUANTITY |
2 |
| CBME |
CUBIC MEASURE |
172800.000 CUBIC INCHES |
| CWZY |
ENVIRONMENTAL CHAMBER TYPE |
TEMPERATURE |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
TEMPERATURE CHAMBER |
| FAAZ |
PHASE |
THREE |
| FEAT |
SPECIAL FEATURES |
TEMPERATURE CHAMBER WITH REMOVABLE HOLDING RACK 1 NEOPRENE PLUG 4.000 IN. DIA. PRESSURE CONTROL PANEL, RUBBER TUBING EA 8.000FT LG., 3 PLUGS |
| MATT |
MATERIAL |
COPPER AND RUBBER CHLOROPRENE CLASS CR LOCATION NOT OTHERWISE SPECIFIED |
| SFTT |
SURFACE TREATMENT |
ZINC AND ENAMEL |
| SUPP |
SUPPLEMENTARY FEATURES |
THE CHAMBER IS USED FOR SUBJECTING ALTIMETERS AND ALTITUDE TRANSDUCER COMPUTERS, SIMILAR TO THE AAU-19/A AND CPU-46/A RESPECTIVELY, TO PRECISELY CONTROLLED TEMPERATURE ENVIRONMENTS DURING SCALE ERROR TESTING |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| FXX4 |
|
Apr-01-1991 |
3 |
H |
D |
SX |
TU |
TU |
| ZH01 |
|
Apr-01-1991 |
|
|
|
|
ZH |
ZH |
| ZW01 |
|
Nov-01-2005 |
|
|
|
|
ZW |
ZW |
| Description: |
BOOTH/CHAMBER/MODULE AUDIO TESTING |
Originating Activity: |
SE |
| Hazardous Material: |
|
National Motor Freight Classification Number: |
027870 |
| Less Than One Truckload: |
C |
NMFC Sub-Item: |
X |
| Uniform Freight Classification Number: |
13660 |
Rail Variance Code: |
1 |
| Less Than One Carload: |
M |
Water Commodity Code: |
652 |
| Type of Cargo Code: |
Z |
Special Handling Code: |
R |
| Air Commodity Special Handling Code: |
VZ |
Air Dimension Code: |
Z |
| Source: |
P |
Primary Inventory Control Activity (PICA) |
Status: |
C |
| Pri/Sec ICC: |
P |
Container NSN: |
|
Category Code: |
|
| Lvl A Pkg Req: |
|
Unit Pack Size: |
68.0x50.0x92.0 |
Pres Material: |
00 |
| Lvl B Pkg Req: |
|
Unit Pack Weight: |
1860.0 |
Pres Method: |
10 |
| Lvl C Pkg Req: |
|
Unit Pack Cube: |
181.018 |
Wrapping Mat: |
XX |
| Opt Proc Ind: |
O |
Unpkg Item Dims: |
|
Spec Marking: |
00 |
| Container FSC: |
|
SPI Number: |
|
SPI Revision: |
|
| Unpkg Weight: |
0.0 |
SPI Date: |
|
Pkg Design Activity: |
|
| Inter Container Qty: |
|
Inter Container Code: |
00 |
Clean/Dry Procedure: |
1 |
| Unit Container: |
FU |
Item Type Storage: |
|
Unit Container Level: |
B |
| |
|
Cush/Dun Material: |
LK |
Cush/Dun Thickness: |
X |
| Source: |
A |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats |
Status: |
H |
| Pri/Sec ICC: |
P |
Container NSN: |
|
Category Code: |
|
| Lvl A Pkg Req: |
|
Unit Pack Size: |
|
Pres Material: |
00 |
| Lvl B Pkg Req: |
|
Unit Pack Weight: |
9999.9 |
Pres Method: |
10 |
| Lvl C Pkg Req: |
|
Unit Pack Cube: |
9999.999 |
Wrapping Mat: |
XX |
| Opt Proc Ind: |
O |
Unpkg Item Dims: |
|
Spec Marking: |
00 |
| Container FSC: |
|
SPI Number: |
|
SPI Revision: |
|
| Unpkg Weight: |
|
SPI Date: |
|
Pkg Design Activity: |
|
| Inter Container Qty: |
|
Inter Container Code: |
00 |
Clean/Dry Procedure: |
1 |
| Unit Container: |
FU |
Item Type Storage: |
|
Unit Container Level: |
|
| |
|
Cush/Dun Material: |
LK |
Cush/Dun Thickness: |
X |
|