National Stock Number(NSN): 6632-01-206-6035 (6632012066035, 012066035)
| NIIN: |
01-206-6035 |
Item Name: |
ANALYZER,BLOOD GAS |
INC: |
38049
|
| FSC: |
6632
|
Assignment Date: |
Apr-20-1985 |
CRIT: |
X |
IIG: |
38049 |
| ISC: |
2 |
Date Standardized: |
Feb-07-2014 |
HMIC: |
N |
DODIC: |
|
| NSC: |
4 |
Cancellation Date: |
Jan-01-2026 |
PMIC: |
A |
FIIG: |
A503U0 |
| ESD: |
|
Schedule B: |
9027.80.3200 |
DEMIL: |
A |
DEMIL INT: |
1 |
| TIIC: |
4 |
Originator: |
KX |
ADPEC: |
0 |
RPDMRC: |
3 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
6630-0285-0000 |
99998
|
DEFENSE SUPPLY CENTER RICHMOND INDUSTRIAL PLANT EQUIPMENT /DLA/ |
H |
6 |
9 |
9 |
PX |
|
|
|
|
|
|
|
G-322 |
64616
|
DEFENSE MEDICAL STANDARDIZATION BOARD |
H |
3 |
2 |
4 |
KX |
|
|
|
|
|
|
Additional Part Information
| Part Number |
CAGE |
Company |
Source |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
| 475691 |
0U6Z4
|
CHIRON DIAGNOSTICS CORP |
CRF |
5 |
2 |
6 |
HD |
|
N |
0 |
|
|
|
| G322 |
64616
|
DEFENSE MEDICAL STANDARDIZATION BOARD |
CRF |
3 |
2 |
4 |
KX |
|
N |
0 |
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DA |
SMS |
Y |
|
0 |
U |
1 |
A |
$7,229.68 |
EA |
|
CQ203N- |
Dec-01-2025 |
H |
| DF |
SMS |
Y |
|
0 |
U |
1 |
F |
$7,229.68 |
EA |
|
------- |
Dec-01-2025 |
H |
| DM |
SMS |
Y |
Z |
0 |
U |
1 |
M |
$7,229.68 |
EA |
|
12B2--- |
Dec-01-2025 |
H |
| DN |
SMS |
Y |
|
0 |
U |
1 |
N |
$7,229.68 |
EA |
|
9B----- |
Dec-01-2025 |
H |
| DS |
SMS |
W |
F |
0 |
U |
1 |
D |
$8,698.52 |
EA |
|
------- |
Oct-01-2022 |
H |
| DS |
SMS |
Y |
F |
0 |
U |
1 |
I |
$7,229.68 |
EA |
|
------- |
Dec-01-2025 |
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DM |
V |
DISCONTINUED WITHOUT REPLACEMENT |
000 |
|
|
|
| DN |
S |
STOCK AS 6630-01-304-2167 |
000 |
|
AAA |
|
| DN |
|
I & S MASTER |
000 |
|
AAB |
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ACDC |
CURRENT TYPE |
AC |
| ACZB |
FREQUENCY RATING |
50.0 HERTZ MINIMUM OR 60.0 HERTZ MAXIMUM |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
BLOOD GAS APPARATUS GAS ANALYZER: 115V 60HZ 170W PH SCALE6.8-8 |
| ELEC |
VOLTAGE IN VOLTS |
120.0 OR 230.0 |
| FEAT |
SPECIAL FEATURES |
200 WATTS; AUTOMATIC; MICROPROCESSOR; C/O A SELF-CONTAINED ELECTRONIC BLOOD/PH GAS ANALYZER SYSTEM,MEASURING PH,PCO2 AND PO2,AND COMPUTING BICARBONATE,TOTAL CO2 AND BASE EXCESS; ACCOMMODATES TWO SAMPLE SIZE; 175 MICROLITERS OR LESS CAPILLARY AND AND 500 MICROLITERS OR LESS SYRINGE; COMPLETE WITH SUPPLIES NECESSARY FOR OPERATION; FOR CONTROL SET,ORDER 6550-01-119-7680; FOR REPLACEMENT REAGENTS ANDCONSUMABLES ORDER THE FOLLOWING; 6830-00-280-9240,6830-01-050-0117,6630-01-166-9527,6630-01-164-6511,6630-01-163-1625,6630-01-163-1626,6550-00-282-4025,6550-00-283-3206,6550-01-148-8966 |
| SUPP |
SUPPLEMENTARY FEATURES |
C/O CONT 6630-01-166-7775; 6630-01-168-7853,6630-01-166-7773,6630-01-166-9526,6630-01-166-9500,6630-00-336-8621,6630-01-166-3506,6630-01-166-7774,5330-01-006-3930,6650-01-080-8912,6550-01-070-1513,6630-01-166-7776,6630-01-166-9524 |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| A911 |
A111 |
Dec-01-2006 |
1 |
G |
Z |
AS |
AM|GX |
AM|BN|GX |
| N9BL |
N9LM |
Dec-01-2006 |
1 |
G |
Z |
GH |
GX|HD |
GH|GX |
| FSGM |
FSKX |
Dec-01-2006 |
1 |
G |
Z |
SS |
GX|TT |
GX|SS|TT |
Replacement & Obsolete Information
| Replaced / Replacement NIIN Information |
| Description: |
APPARATUS CHEMICAL LABORATORY |
Originating Activity: |
KX |
| Hazardous Material: |
|
National Motor Freight Classification Number: |
014500 |
| Less Than One Truckload: |
F |
NMFC Sub-Item: |
X |
| Uniform Freight Classification Number: |
06350 |
Rail Variance Code: |
|
| Less Than One Carload: |
|
Water Commodity Code: |
652 |
| Type of Cargo Code: |
Z |
Special Handling Code: |
9 |
| Air Commodity Special Handling Code: |
EZ |
Air Dimension Code: |
A |
| Source: |
P |
Primary Inventory Control Activity (PICA) |
Status: |
H |
| Pri/Sec ICC: |
P |
Container NSN: |
|
Category Code: |
ZZZZ |
| Lvl A Pkg Req: |
Z |
Unit Pack Size: |
|
Pres Material: |
ZZ |
| Lvl B Pkg Req: |
|
Unit Pack Weight: |
0.0 |
Pres Method: |
ZZ |
| Lvl C Pkg Req: |
|
Unit Pack Cube: |
0.000 |
Wrapping Mat: |
ZZ |
| Opt Proc Ind: |
A |
Unpkg Item Dims: |
|
Spec Marking: |
ZZ |
| Supp Inst: |
APPLICABLE TO ALL MEDICAL |
| Container FSC: |
|
SPI Number: |
MPACG00001 |
SPI Revision: |
|
| Unpkg Weight: |
|
SPI Date: |
Mar-30-1988 |
Pkg Design Activity: |
89875
|
| Inter Container Qty: |
|
Inter Container Code: |
|
Clean/Dry Procedure: |
Z |
| Unit Container: |
ZZ |
Item Type Storage: |
|
Unit Container Level: |
|
| |
|
Cush/Dun Material: |
ZZ |
Cush/Dun Thickness: |
Z |
|