National Stock Number(NSN): 6630-01-343-8132 (6630013438132, 013438132)
| NIIN: |
01-343-8132 |
Item Name: |
CHROMATOGRAPH,GAS |
INC: |
61620
|
| FSC: |
6630
|
Assignment Date: |
Aug-16-1991 |
CRIT: |
X |
IIG: |
61620 |
| ISC: |
5 |
Date Standardized: |
Aug-16-1991 |
HMIC: |
N |
DODIC: |
|
| NSC: |
4 |
Cancellation Date: |
Jun-01-2013 |
PMIC: |
A |
FIIG: |
A23900 |
| ESD: |
|
Schedule B: |
9027.20.2000 |
DEMIL: |
A |
DEMIL INT: |
6 |
| TIIC: |
4 |
Originator: |
97 |
ADPEC: |
0 |
RPDMRC: |
2 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
8500 |
34682
|
PERKIN-ELMER CORP THE INDUSTRIAL PRODUCTS DIV |
H |
5 |
9 |
4 |
KX |
|
B |
|
|
|
|
|
A95 TRZ095 |
66732
|
DEPARTMENT OF THE ARMY U S ARMY MEDICAL MATERIAL AGENCY MCMR-MMO-SA |
H |
5 |
1 |
4 |
KX |
|
|
|
|
|
|
|
PE8500 |
34682
|
PERKIN-ELMER CORP THE INDUSTRIAL PRODUCTS DIV |
H |
3 |
9 |
4 |
KX |
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DA |
SMS |
L |
|
0 |
U |
1 |
A |
$27,546.50 |
EA |
|
RQ100N- |
Oct-01-2012 |
H |
| DS |
SMS |
Y |
|
0 |
U |
0 |
D |
$27,546.50 |
EA |
|
------- |
May-01-2013 |
H |
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| FEAT |
SPECIAL FEATURES |
INJECTOR AND DETECTOR SETTABLE RANGE: OFF OR 1 DEG C TO 450 DEG C PORM 1 DEG C; SOFT KEY USER INTERACTION BY KEYBOARD AND VDU; CHROMATOGRAM DISPLAYED ON SCREEN (OPTIONAL); 10 ANALYTICAL METHODS CAN BE CREATED AND STORED; NOTE: REQUISITIONER MUST SPECIFY INJECTOR,DETECTOR AND PNEUMATIC CONFIGURATIONS |
| TEXT |
GENERAL CHARACTERISTICS ITEM DESCRIPTION |
FOR SINGLE OR DUAL DETECTOR; EXTENSIVE RANGE OF COMBINATIONS FROM SIX DETECTOR TYPES; PACKED,CAPILLARY OR COMBINED INJECTOR SYSTEMS SIMULTANEOUSLY INSTALLED; AUTOMATED BLEED COMPENSATION FOR BOTH DETECTOR SIGNALS; SWITCHING BETWEEN TWO DETECTOR SIGNALS GIVES FLEXIBILITY FOR DUAL DETECTOR ANALYTICAL SYSTEMS; WIDE RANGE OF PNEUMATIC MODELES ALLOWS OPTIMUM CONTROL OF CARRIER AND DETECTOR GASES; SPECIALIZED CAPILLARY COLUMN PNEUMATICS PROVIDE EASE OF ADJUSTMENT AND RESETTABILITY OF COLUMN HEAD PRESSURE; OVEN HAS SLIDING DOOR ACCESS; OVERALL OPERATING RANGE OF OVEN 80 DEG C TO 500 DEG C; 117V PORM 10 PCT; 60 HZ; BATTERY BACK-UP TO 1 YEAR DEPENDING ON CONFIGURATION; TOTAL H W/VDU 30.75 IN.; TOTAL W W/VDU 38.5 IN.; TOTAL DEPTH W/VDU 38.25 IN.; TOTAL WT OF ANALYZER AND KEYBOARD UNIT AND VDU UNIT 154 LB |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| A910 |
A923 |
Mar-01-2007 |
3 |
Z |
Z |
CD |
GX|CD |
AM|BN|CD|GX |
|