National Stock Number(NSN): 6630-01-102-5757 (6630011025757, 011025757)
| NIIN: |
01-102-5757⛔ |
Item Name: |
ANALYZER,ELECTROLYTIC SOLUTION |
INC: |
10948
|
| FSC: |
6630
|
Assignment Date: |
Oct-22-1980 |
CRIT: |
X |
IIG: |
10948 |
| ISC: |
3 |
Date Standardized: |
Mar-29-2000 |
HMIC: |
N |
DODIC: |
|
| NSC: |
5 |
Cancellation Date: |
Aug-07-2002 |
PMIC: |
A |
FIIG: |
A503U0 |
| ESD: |
A |
Schedule B: |
|
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
4 |
Originator: |
KX |
ADPEC: |
0 |
RPDMRC: |
3 |
| NIIN: |
01-104-2901 |
Item Name: |
ANALYZER,ELECTROLYTIC SOLUTION |
| FSC: |
6630 |
Replacement Date: |
Aug-07-2002 |
|
INC: |
10948 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
200 |
56115
|
FRYS METALS INC |
H |
3 |
2 |
2 |
MB |
4 |
D |
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DF |
FLZ |
L |
U |
0 |
U |
1 |
L |
$0.00 |
EA |
|
LP*RH-N |
Sep-01-2000 |
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DF |
F |
WHN EXHST USE 6630-01-165-0201 |
000 |
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ABRN |
HEIGHT |
24.000 INCHES |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL |
| AKYD |
ACCESSORY COMPONENTS AND QUANTITY |
RESISTIVITY INDICATOR, CHART RECORDER, GRADUATED TEST CELL, RESERVIOR, SOLUTION PUMP, ION REMOVAL SYSTEM, SOLUTION RECOVERY SYSTEM, OVERFLOW SYPHONSYSTEM |
| APYE |
DETECTOR TYPE |
DISCHARGE IONIZATION |
| AQXY |
TEST TYPE FOR WHICH DESIGNED |
CONTAMINATION OF CIRCUIT CARDS |
| CYFV |
METHOD OF ANALYSIS |
ELECTROGRAVIMETRIC |
| CYFX |
ELECTRODE TYPE |
NOT INCLUDED AS AN ESSENTIAL CHARACTERISTIC IN THE SPECIFICATION/CID COVERING THIS STANDARD NSN |
| CYFZ |
TEST SAMPLE/SPECIMEN SIZE |
CIRCUIT CARDS 8 BY 9 INCHES |
| CYGB |
TEST SAMPLE/SPECIMEN HOLDING DEVICE |
ELECTROLYSIS VESSEL |
| CYGC |
REAGENT/DILUENT HOLDING DEVICE |
ELECTROLYSIS VESSEL |
| CYGD |
THROUGHPUT PER HOUR |
6 SAMPLES/SPECIMENS MAXIMUM |
| DPTH |
DEPTH |
29.500 INCHES |
| ELEC |
VOLTAGE IN VOLTS |
115.0 |
| FEAT |
SPECIAL FEATURES |
TESTER, ION CONTAMINATION; DETERMINES LEVELS OF CLEANLINESS OF ELECTRONIC COMPONENTS BY MEASURING THE RESISTIVITY OF A GIVEN QUANTITY OF SOLUTION USED TO EXTRACT CONTAMINANTS, MEASURED IN MEGOHMS AND A SLIDE RULE CONVERSION CHART TO NACL PER SQUARE INCH; TWO STEP OPERATION |
| WDTH |
WIDTH |
24.500 INCHES |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| FGG4 |
FEE4 |
Sep-01-2000 |
0 |
0 |
D |
|
TU |
TU |
Replacement & Obsolete Information
| Replaced / Replacement NIIN Information |
| FSC |
NIIN |
ISC |
Originator |
NSC |
Std. Date |
Status |
|
6630
|
01-165-0201
|
1 |
KX |
0 |
Mar-29-2000 |
H |
|