|
National Stock Number(NSN): 6625-00-893-0122 (6625008930122, 008930122)
| NIIN: |
00-893-0122⛔ |
Item Name: |
TEST SET,ELECTRICAL POWER |
INC: |
03637
|
| FSC: |
6625
|
Assignment Date: |
Jan-01-1962 |
CRIT: |
X |
IIG: |
03637 |
| ISC: |
3 |
Date Standardized: |
Feb-20-2002 |
HMIC: |
P |
DODIC: |
|
| NSC: |
0 |
Cancellation Date: |
|
PMIC: |
A |
FIIG: |
T228-A |
| ESD: |
A |
Schedule B: |
9030.90.8030 |
DEMIL: |
A |
DEMIL INT: |
7 |
| TIIC: |
1 |
Originator: |
TX |
ADPEC: |
0 |
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
A/M24T-8() |
80058
|
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM |
C |
5 |
1 |
4 |
ZZ |
|
|
|
|
|
|
|
GPT5B |
82386
|
JAIDINGER MFG CO INC |
C |
3 |
2 |
4 |
SB |
3 |
D |
|
|
|
|
|
MIL-T-26922 |
81349
|
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M |
C |
4 |
1 |
4 |
ZZ |
|
|
|
|
|
|
|
AM24T8 |
81349
|
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M |
H |
4 |
1 |
4 |
SB |
3 |
D |
|
|
|
|
|
MIL-HDBK-300(ATS) |
1HBK1
|
MIL-HDBK-300 HQ AFMC-LGIS |
H |
5 |
1 |
4 |
ZZ |
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DA |
FPZ |
V |
|
0 |
U |
1 |
A |
$13,439.00 |
EA |
|
GP100N- |
Oct-01-1999 |
H |
| DF |
FLZ |
V |
U |
0 |
U |
1 |
L |
$13,439.00 |
EA |
|
--MRH-N |
Dec-01-2019 |
C |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DA |
V |
DISCONTINUED W/O REPLACEMENT |
000 |
|
|
|
| DF |
F |
WHN EXHST USE 6625-01-524-3180 |
000 |
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ABGL |
WIDTH |
60.000 INCHES NOMINAL |
| ABRY |
LENGTH |
118.000 INCHES NOMINAL |
| ACYN |
AC VOLTAGE RATING |
120.0 VOLTS NOMINAL AND 208.0 VOLTS NOMINAL AND 240.0 VOLTS NOMINAL AND 440.0 VOLTS NOMINAL LOCATION NOT OTHERWISE SPECIFIED |
| ACYR |
DC VOLTAGE RATING |
28.0 VOLTS NOMINAL LOCATION NOT OTHERWISE SPECIFIED |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL LOCATION NOT OTHERWISE SPECIFIED |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| ANPZ |
ENCLOSURE FEATURE |
SINGLE ITEM W/HOUSING |
| AQXY |
TEST TYPE FOR WHICH DESIGNED |
INTENDED FOR USE IN TESTING ALL POWER SUPPLIES THAT ARE USED FOR ELECTRICAL GROUND SUPPORT |
| FAAZ |
PHASE |
THREE LOCATION NOT OTHERWISE SPECIFIED |
| FEAT |
SPECIAL FEATURES |
MOBILE TEST SET; FURNISHES A 3 PHASE, WYE CONNECTED LOAD; CAN BE TOWED; INCLUDES SWITCHES, CONTROL POWER INDICATOR LIGHT, COOLING FANS, CONTROL CONSOLE, CONTROL PANEL, ELECTRIC METERS, INCLUDING FREQUENCY METER, WATTMETER, POWER FACTOR METER, VOLTMETER, AMMETER, ELAPSED TIME INDICATOR, PHASE SEQUENCE INDICATOR; ALSO HAS SELECTOR SWITCH AND FIRE EXTINGUISHER |
| HGTH |
HEIGHT |
60.500 INCHES NOMINAL |
| MATT |
MATERIAL |
STEEL HOUSING |
| RDAL |
REFERENCE DATA AND LITERATURE |
T.O. 33AA7-56-24 |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| FGG4 |
FEE4 |
Sep-01-2000 |
0 |
0 |
D |
|
TU |
TU |
| ZH01 |
|
Apr-01-1991 |
|
|
|
|
ZH |
ZH |
| VJ01 |
|
Dec-01-2018 |
|
|
|
|
VJ |
VJ |
Replacement & Obsolete Information
| Replaced / Replacement NIIN Information |
| FSC |
NIIN |
ISC |
Originator |
NSC |
Std. Date |
Status |
|
6625
|
00-988-5713
|
1 |
TX |
0 |
Jan-07-1985 |
C |
| Description: |
ELEC APPLIANCES/INSTRUMENTS NOI |
Originating Activity: |
XX |
| Hazardous Material: |
|
National Motor Freight Classification Number: |
061700 |
| Less Than One Truckload: |
W |
NMFC Sub-Item: |
Z |
| Uniform Freight Classification Number: |
34580 |
Rail Variance Code: |
|
| Less Than One Carload: |
P |
Water Commodity Code: |
738 |
| Type of Cargo Code: |
3 |
Special Handling Code: |
9 |
| Air Commodity Special Handling Code: |
HQ |
Air Dimension Code: |
A |
| Source: |
P |
Primary Inventory Control Activity (PICA) |
Status: |
C |
| Pri/Sec ICC: |
P |
Container NSN: |
|
Category Code: |
ZZZ0 |
| Lvl A Pkg Req: |
|
Unit Pack Size: |
107.0x60.0x61.0 |
Pres Material: |
00 |
| Lvl B Pkg Req: |
|
Unit Pack Weight: |
3598.0 |
Pres Method: |
ZZ |
| Lvl C Pkg Req: |
|
Unit Pack Cube: |
226.631 |
Wrapping Mat: |
ZZ |
| Opt Proc Ind: |
A |
Unpkg Item Dims: |
|
Spec Marking: |
ZZ |
| Container FSC: |
|
SPI Number: |
F008930122 |
SPI Revision: |
|
| Unpkg Weight: |
0.0 |
SPI Date: |
Apr-21-1966 |
Pkg Design Activity: |
|
| Inter Container Qty: |
000 |
Inter Container Code: |
00 |
Clean/Dry Procedure: |
Z |
| Unit Container: |
ZZ |
Item Type Storage: |
|
Unit Container Level: |
B |
| |
|
Cush/Dun Material: |
ZZ |
Cush/Dun Thickness: |
Z |
| Source: |
A |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats |
Status: |
H |
| Pri/Sec ICC: |
P |
Container NSN: |
|
Category Code: |
|
| Lvl A Pkg Req: |
|
Unit Pack Size: |
|
Pres Material: |
00 |
| Lvl B Pkg Req: |
|
Unit Pack Weight: |
9999.9 |
Pres Method: |
ZZ |
| Lvl C Pkg Req: |
|
Unit Pack Cube: |
9999.999 |
Wrapping Mat: |
ZZ |
| Opt Proc Ind: |
A |
Unpkg Item Dims: |
|
Spec Marking: |
ZZ |
| Container FSC: |
|
SPI Number: |
F008930122 |
SPI Revision: |
|
| Unpkg Weight: |
|
SPI Date: |
|
Pkg Design Activity: |
|
| Inter Container Qty: |
|
Inter Container Code: |
00 |
Clean/Dry Procedure: |
Z |
| Unit Container: |
ZZ |
Item Type Storage: |
|
Unit Container Level: |
|
| |
|
Cush/Dun Material: |
ZZ |
Cush/Dun Thickness: |
Z |
|