| MRC |
Requirement Statement |
Reply Statement |
| ABHP |
OVERALL LENGTH |
18.500 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
3.500 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
11.000 INCHES NOMINAL |
| AFBH |
INDIVIDUAL SECTION QUANTITY |
2 |
| AGTA |
BASIC SHAPE STYLE |
1 RECTANGULAR OR SQUARE |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| ALBM |
OPERATING CONTROL METHOD |
MANUAL |
| AMQY |
INSTALLATION DESIGN |
PORTABLE |
| AQZF |
CONTROL TYPE |
LOCAL |
| AWLS |
CONNECTION TYPE |
TERMINAL BLOCK W/SCREW FRONT |
| BHSX |
CIRCUIT CONSTRUCTION TYPE |
SOLID STATE |
| BHTB |
FREQUENCY PER CHANNEL |
0.1 HERTZ MINIMUM OPERATING CHANNEL |
| BHTB |
FREQUENCY PER CHANNEL |
10.0 MEGAHERTZ MAXIMUM OPERATING CHANNEL |
| BHTD |
FREQUENCY ADJUSTMENT TYPE |
STEPPED |
| BHTF |
INDIVIDUAL STEP FREQUENCY |
1.0 HERTZ AND 10.0 HERTZ AND 100.0 HERTZ AND 1.0 KILOHERTZ AND 10.0 KILOHERTZ AND 100.0 KILOHERTZ AND 1.0 MEGAHERTZ AND 10.0 MEGAHERTZ |
| BHTQ |
PULSE RISE TIME PER CHANNEL |
5.000 NANOSECONDS NOMINAL OPERATING CHANNEL |
| BHTR |
PULSE DECAY TIME PER CHANNEL |
35.000 NANOSECONDS MINIMUM OPERATING CHANNEL |
| BHTR |
PULSE DECAY TIME PER CHANNEL |
10.000 MILLISECONDS MAXIMUM OPERATING CHANNEL |
| BHTS |
POLARITY PER CHANNEL |
NEGATIVE OPERATING CHANNEL |
| BHTS |
POLARITY PER CHANNEL |
POSITIVE OPERATING CHANNEL |
| BHTT |
PULSE REPETITION RATE PER CHANNEL |
1.000 PULSES PER SECOND NOMINAL OPERATING CHANNEL |
| BHTT |
PULSE REPETITION RATE PER CHANNEL |
10.000 PULSES PER SECOND NOMINAL OPERATING CHANNEL |
| BHTT |
PULSE REPETITION RATE PER CHANNEL |
100.000 PULSES PER SECOND NOMINAL OPERATING CHANNEL |
| BHTT |
PULSE REPETITION RATE PER CHANNEL |
1.000 KILOPULSES PER SECOND NOMINAL OPERATING CHANNEL |
| BHTT |
PULSE REPETITION RATE PER CHANNEL |
10.000 KILOPULSES PER SECOND NOMINAL OPERATING CHANNEL |
| BHTT |
PULSE REPETITION RATE PER CHANNEL |
100.000 KILOPULSES PER SECOND NOMINAL OPERATING CHANNEL |
| BHTT |
PULSE REPETITION RATE PER CHANNEL |
1.000 MEGAPULSES PER SECOND NOMINAL OPERATING CHANNEL |
| BHTT |
PULSE REPETITION RATE PER CHANNEL |
10.000 MEGAPULSES PER SECOND NOMINAL OPERATING CHANNEL |
| BHTZ |
SIGNAL DATA TYPE PER CHANNEL |
OPERATING CHANNEL PULSE |
| BJBJ |
OUTPUT WAVE SHAPE |
PULSE, TRIGGER |
| BJBQ |
OPERATING AC FREQUENCY IN HERTZ |
50.0 MINIMUM 1ST VOLTAGE |
| BJBQ |
OPERATING AC FREQUENCY IN HERTZ |
400.0 MAXIMUM 2ND VOLTAGE |
| BJBW |
CONNECTION CONTACT TYPE AND QUANTITY |
6 RECEPTACLE, COAXIAL INTERNAL |
| BKFC |
EXTERNAL AC OPERATING VOLTAGE IN VOLTS |
115.0 MINIMUM 1ST VOLTAGE |
| BKFC |
EXTERNAL AC OPERATING VOLTAGE IN VOLTS |
220.0 MAXIMUM 2ND VOLTAGE |
| FAAZ |
PHASE |
SINGLE |
| FCLS |
FUNCTIONAL CLASSIFICATION |
BB-1.1 |
| NTRD |
ENTRY DATE |
90-10-01 |
| ZZZV |
FSC APPLICATION DATA |
SUPPORT OF AN/TPN19 AND AN/MPS-T1 |