National Stock Number(NSN): 6625-00-229-1045 (6625002291045, 002291045)
| NIIN: |
00-229-1045 |
Item Name: |
TEST SET,RELAY |
INC: |
03667
|
| FSC: |
6625
|
Assignment Date: |
Jan-01-1963 |
CRIT: |
N |
IIG: |
03667 |
| ISC: |
5 |
Date Standardized: |
Feb-01-1975 |
HMIC: |
P |
DODIC: |
|
| NSC: |
4 |
Cancellation Date: |
Jun-13-2000 |
PMIC: |
U |
FIIG: |
T228-A |
| ESD: |
|
Schedule B: |
|
DEMIL: |
B |
DEMIL INT: |
|
| TIIC: |
1 |
Originator: |
98 |
ADPEC: |
|
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
318 |
81341
|
FEDERAL AVIATION ADMINISTRATION |
H |
3 |
2 |
X |
XX |
3 |
D |
|
|
|
|
|
CA405A |
81341
|
FEDERAL AVIATION ADMINISTRATION |
H |
3 |
2 |
X |
XX |
3 |
D |
|
|
|
|
|
MILT3097TYPEI193 |
81349
|
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M |
H |
2 |
2 |
X |
XX |
3 |
D |
|
|
|
|
|
SCDL4837 |
80063
|
US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR |
H |
3 |
2 |
X |
XX |
3 |
D |
|
|
|
|
|
X61864A |
64959
|
AMERICAN TELEPHONE AND TELEGRAPH CO |
H |
3 |
2 |
X |
XX |
3 |
D |
|
|
|
|
|
X61864A |
70408
|
AT AND T CORP |
H |
5 |
9 |
2 |
MB |
3 |
D |
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DA |
B16 |
V |
|
0 |
U |
1 |
A |
$243.00 |
EA |
|
GP1TDN- |
Oct-01-1995 |
H |
| DF |
FPZ |
Y |
S |
0 |
U |
1 |
L |
$243.00 |
EA |
|
--M---N |
Mar-01-1999 |
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DA |
V |
DISCONTINUED W/O REPLACEMENT |
000 |
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ABGL |
WIDTH |
12.700 INCHES NOMINAL |
| ABRY |
LENGTH |
23.000 INCHES NOMINAL |
| ACYR |
DC VOLTAGE RATING |
115.0 VOLTS MINIMUM |
| ACYR |
DC VOLTAGE RATING |
130.0 VOLTS MAXIMUM |
| ALSF |
INTERNAL BATTERY ACCOMMODATION |
NOT INCLUDED |
| ANNQ |
MATERIAL AND LOCATION |
WOOD CARRYING CASE |
| ANPZ |
ENCLOSURE FEATURE |
SINGLE ITEM W/CARRYING CASE |
| AQXY |
TEST TYPE FOR WHICH DESIGNED |
TESTING POLAR RELAYS |
| AQXZ |
OPERATING TEST CAPABILITY |
AMMETER; RANGE 100-0-100 MA DC |
| FEAT |
SPECIAL FEATURES |
A. PROVIDES A SOURCE OF OPENS AND CLOSURES AT A FREQUENCYOF EITHER 20 CYCLES OR 10 CYCLES PER SECOND FOR LINING UP TELEGRAPH CIRCUITS |
| HGTH |
HEIGHT |
11.300 INCHES NOMINAL |
| ZZZT |
NONDEFINITIVE SPEC/STD DATA |
I-193 TYPE |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| YB01 |
|
Feb-24-1992 |
|
|
|
|
YB |
YB |
| ZH01 |
|
Apr-01-1991 |
|
|
|
|
ZH |
ZH |
| ZP01 |
|
Apr-01-1991 |
|
|
|
|
ZP |
ZP |
| ZU01 |
|
Apr-01-1991 |
|
|
|
|
ZU |
ZU |
Replacement & Obsolete Information
| Obsolete NIIN Information |
|