National Stock Number(NSN): 6525-01-507-1623 (6525015071623, 015071623)
| NIIN: |
01-507-1623 |
Item Name: |
COMPUTED TOMOGRAPHY SCANNER,FIELD |
INC: |
77777 |
| FSC: |
6525
|
Assignment Date: |
Apr-22-2003 |
CRIT: |
X |
IIG: |
77777 |
| ISC: |
2 |
Date Standardized: |
Oct-04-2023 |
HMIC: |
P |
DODIC: |
|
| NSC: |
0 |
Cancellation Date: |
|
PMIC: |
A |
FIIG: |
A23900 |
| ESD: |
|
Schedule B: |
|
DEMIL: |
A |
DEMIL INT: |
1 |
| TIIC: |
4 |
Originator: |
KX |
ADPEC: |
|
RPDMRC: |
1 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
03-0707 |
89875
|
DEFENSE LOGISTICS AGENCY DIRECTORATE OF MEDICAL MATERIEL DEFENSE SUPPLY CENTER PHILADELPHIA |
C |
3 |
2 |
4 |
ZZ |
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DA |
SMS |
W |
|
0 |
U |
1 |
A |
$468,117.44 |
EA |
|
CQ203N- |
Oct-01-2025 |
C |
| DF |
SMS |
W |
|
0 |
U |
1 |
F |
$468,117.44 |
EA |
|
------- |
Oct-01-2025 |
C |
| DN |
SMS |
W |
|
0 |
U |
1 |
N |
$468,117.44 |
EA |
|
9B----A |
Oct-01-2025 |
C |
| DS |
SMS |
W |
F |
0 |
U |
1 |
D |
$563,223.94 |
EA |
|
------- |
Oct-01-2022 |
H |
| DS |
SMS |
W |
F |
0 |
U |
1 |
I |
$468,117.44 |
EA |
|
------- |
Oct-01-2025 |
C |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DN |
S |
STOCK AS 6525-01-511-7357 |
000 |
|
AAA |
|
| DN |
S |
STOCK AS 6525-01-560-1408 |
000 |
|
AAB |
|
| DN |
|
I & S MASTER |
000 |
|
AAC |
|
| DS |
|
I&S MASTER |
000 |
|
AAB |
|
| DS |
S |
STOCK AS 6525-01-511-7357 |
000 |
|
AAA |
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
COMPUTED TOMOGRAPHY SCANNER FIELD 208 VAC 50-60HZ EA |
| FEAT |
SPECIAL FEATURES |
SUITABLE FOR FIXED AND FIELD MILITARY MTF; 280VAC + OR - 10%, 3 PHASE, 50/60 HZ+ OR -2HZ, 8% LINE REGULATION COMMERCIAL POWER OR 100 KW GENERATORS USED BY AMEDD TOE AND OTHER KW; INSTANTANEOUS POWER DEMAND NOT EXCEEDING 75KW; SHAL NOT REQUIRE BETTER THAN 10% LINE VOLTAGE REGULATION WHEN OPERATING AT MAX LINE CURRENT SETTING;PRIMARY DISCONNECT MEANS FROM LOCATION READILY ACCESSIBLE BY OPERATOR; AMPACITY OF CIRCUIT BREAKER RATED AT LEAST 50% OF MONETARY MAX RATING OF EQUIP; SIZED TO ACCOMMODATE 2 AWG CONDUCTORS; COTS SCANNER AND ALL MAJOR COMPONENTS AND CERTIFIED 21 CFR REQUIREMENTS; ADDITIONAL COMPONETS TO FIT INSIDE ISO SHELTER FOR STORAGE AND USE MAY BE REQUIRED; C/O CT GANTRY; OPERATIOR CONTROL, PATIENT SUPPORT. SYSTEM CAPABLE OF BEING INSTALLED AND OPERATED IN ISO SHELTERS, GANTRY TILT OF +/- 25 DEG; PATIENT TABLE; DISPLAY CONSOLE; CT IMAGE OUTPUT FROM CT COMPUTER VIA OPTICAL DISK |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| A911 |
A111 |
Dec-01-2006 |
1 |
G |
|
|
AM|GX |
AM|BN|GX |
| N9BL |
N9LM |
Dec-01-2006 |
1 |
G |
|
|
GX |
GH|GX |
| FSGM |
FSKX |
Dec-01-2006 |
1 |
G |
|
|
GX|TT |
GX|SS|TT |
Replacement & Obsolete Information
| Replaced / Replacement NIIN Information |
| Description: |
X-RAY MACHINE |
Originating Activity: |
KX |
| Hazardous Material: |
|
National Motor Freight Classification Number: |
063560 |
| Less Than One Truckload: |
W |
NMFC Sub-Item: |
Z |
| Uniform Freight Classification Number: |
98185 |
Rail Variance Code: |
|
| Less Than One Carload: |
|
Water Commodity Code: |
656 |
| Type of Cargo Code: |
Z |
Special Handling Code: |
9 |
| Air Commodity Special Handling Code: |
MZ |
Air Dimension Code: |
A |
|