National Stock Number(NSN): 6525-01-192-1884 (6525011921884, 011921884)
| NIIN: |
01-192-1884 |
Item Name: |
X-RAY APPARATUS,RADIOGRAPHIC AND FLUOROSCOPIC |
INC: |
06321
|
| FSC: |
6525
|
Assignment Date: |
Oct-17-1984 |
CRIT: |
N |
IIG: |
06321 |
| ISC: |
2 |
Date Standardized: |
Aug-04-1986 |
HMIC: |
P |
DODIC: |
|
| NSC: |
5 |
Cancellation Date: |
Feb-01-2005 |
PMIC: |
A |
FIIG: |
T140-C |
| ESD: |
|
Schedule B: |
|
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
1 |
Originator: |
KX |
ADPEC: |
|
RPDMRC: |
|
| NIIN: |
01-189-3986 |
Item Name: |
X-RAY APPARATUS,RADIOGRAPHIC AND FLUOROSCOPIC |
| FSC: |
6525 |
Replacement Date: |
Feb-01-2005 |
|
INC: |
06321 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
DXD 350-II (MOD) W/PROVISIONING |
24456
|
GENERAL ELECTRIC CO MEDICAL SYSTEMS DIV |
H |
3 |
2 |
4 |
KX |
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DA |
S9M |
X |
H |
0 |
U |
1 |
A |
$148,625.80 |
EA |
|
CQ103N- |
Oct-01-2003 |
H |
| DF |
S9M |
X |
|
0 |
U |
1 |
F |
$148,625.80 |
EA |
|
------- |
Oct-01-2003 |
H |
| DM |
S9M |
V |
Z |
0 |
U |
1 |
M |
$107,639.85 |
EA |
|
13M2--- |
Oct-01-2000 |
H |
| DN |
S9M |
J |
|
0 |
U |
1 |
N |
$148,625.80 |
EA |
|
9L----- |
Oct-01-2003 |
H |
| DS |
S9M |
X |
|
0 |
U |
1 |
D |
$148,625.80 |
EA |
|
------- |
Oct-01-2003 |
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DM |
V |
DISCONTINUED W/O REPLACEMENT |
000 |
|
|
|
| DN |
J |
INTRCHNGBL W/ 6525-01-130-4930 |
000 |
|
|
|
| DN |
J |
INTRCHNGBL W/ 6525-01-283-1076 |
000 |
|
|
|
| DN |
J |
INTRCHNGBL W/ 6525-01-312-6411 |
000 |
|
|
|
| DN |
3 |
REV OF P/C S 6525-01-189-3986 |
000 |
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| AKCV |
DRIVE TYPE |
MOTOR |
| AKYD |
ACCESSORY COMPONENTS AND QUANTITY |
ADJ NON-SKID FOOTREST-1; COMPRESSION-IMMOBILIGING DEVICE-1; HEAD CLAMP-1; PATIENT GRASP HANDLES-1; SKIDPROOF PATIENT STEP-1; SHOULDER REST-1 |
| APGF |
DESIGN TYPE |
STATIONARY |
| ARNF |
TUBE QUANTITY |
2 |
| ARQE |
ELECTRIC POWER RATING |
45000.0 WATTS NOMINAL |
| AWGH |
TUBE TYPE |
DOUBLE FOCUS, ROTATING ANODE FLUOROSCOPIC AND DOUBLE FOCUS, ROTATING ANODE RADIOGRAPHIC |
| BNBB |
TABLE TYPE |
TILTING |
| BPKZ |
RECTIFICATION TYPE |
FULL-WAVE |
| CLPG |
TUBE COOLING METHOD |
AIR |
| CLPH |
TUBE MOUNTING TYPE |
TABLE AND TUBE STAND |
| CLPR |
TUBE STAND MOUNTING TYPE |
FLOOR TO CEILING |
| CLPS |
FLOOR TO CEILING HEIGHT RANGE |
ANY ACCEPTABLE |
| CLPT |
TILT RANGE |
90DEGREES VERTICAL AND 15 DEGREES TRENDLEBERG |
| CLPW |
BUCKY DIAPHRAGM |
INCLUDED |
| CLQD |
TRANSFORMER RECTIFICATION METHOD |
SELF-RECTIFYING |
| CLQF |
TRANSFORMER OUTPUT CAPACITY |
TO 300 MA AT 150 KV PEAK |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
X-RAY APPARATUS: HIGH CAPACITY RADIOGRAPHIC AND FLUROSCOPIC |
| ELEC |
VOLTAGE IN VOLTS |
190.0 AND 270.0 |
| FAAZ |
PHASE |
SINGLE |
| FEAT |
SPECIAL FEATURES |
50/60 HZ,AC; W/ROTATING ANODE; DESIGNED FOR USE W/IMAGE INTENSIFIER; C/O SOLID STATE CONTROL UNIT,TRANSORMER W/SOLID STATE RECTIFIERS; 45 FT RADIOGRAPHIC AND 25 FT FLUOROSCOPIC HIGH VOLTAGE CABLES; COLLIMATOR,24 BY 24 CM FRONT END-LOADING,SPOT-FILM DEVICE; BUCKY DIAPHRAGM,FLOOR-TO CEILING FLOOR MT,AND VERT CASSETTE HOLDER |
| FREQ |
FREQUENCY IN HERTZ |
50.0 OR 60.0 |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| A111 |
|
Apr-01-1991 |
1 |
Z |
|
|
|
|
| FSKX |
|
Apr-01-1991 |
1 |
Z |
|
|
|
|
|