National Stock Number(NSN): 6525-01-070-1547 (6525010701547, 010701547)
| NIIN: |
01-070-1547 |
Item Name: |
X-RAY APPARATUS,RADIOGRAPHIC,MEDICAL |
INC: |
06320
|
| FSC: |
6525
|
Assignment Date: |
Jan-05-1979 |
CRIT: |
X |
IIG: |
06320 |
| ISC: |
2 |
Date Standardized: |
May-08-1979 |
HMIC: |
P |
DODIC: |
|
| NSC: |
6 |
Cancellation Date: |
Nov-15-2012 |
PMIC: |
A |
FIIG: |
T140-C |
| ESD: |
|
Schedule B: |
9022.14.0000 |
DEMIL: |
A |
DEMIL INT: |
1 |
| TIIC: |
1 |
Originator: |
KX |
ADPEC: |
|
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
MOBIFLEX W-TABLE PERCEPT H |
53289
|
THOMSON-CGR CORP |
C |
3 |
9 |
4 |
KX |
1 |
D |
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DA |
SMS |
Y |
H |
0 |
U |
1 |
A |
$40,068.00 |
EA |
|
CQ103N- |
Dec-01-2015 |
H |
| DF |
|
Y |
|
|
|
|
F |
$0.00 |
EA |
|
------- |
Jan-01-2016 |
H |
| DN |
SMS |
Y |
|
0 |
U |
1 |
N |
$40,068.00 |
EA |
|
9B----- |
Dec-01-2015 |
H |
| DS |
SMS |
Y |
F |
0 |
U |
1 |
D |
$40,068.00 |
EA |
|
------- |
Dec-01-2015 |
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DA |
V |
DISCONTINUED W/O REPLACEMENT |
000 |
|
|
|
| DF |
V |
DISCONTINUED W/O REPLACEMENT |
000 |
|
|
|
| DN |
V |
DISCONTINUED W/O REPLACEMENT |
000 |
|
|
|
| DS |
V |
DISCONTINUED W/O REPLACEMENT |
000 |
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| AAXX |
MOUNTING TYPE |
MOBILE |
| AKYD |
ACCESSORY COMPONENTS AND QUANTITY |
INSTALLATION,CALIBRATION,MAINTENANCE,OPERATOR MANUAL SETS 2; FIELD USE BUCKY TABLE 1 |
| AMPS |
CURRENT RATING IN AMPS |
75.0 |
| APGF |
DESIGN TYPE |
MOBILE |
| APHE |
OPERATION METHOD |
MANUAL |
| AQZF |
CONTROL TYPE |
CABINET |
| ARNF |
TUBE QUANTITY |
1 |
| ARQE |
ELECTRIC POWER RATING |
25000.0 WATTS NOMINAL |
| AWGH |
TUBE TYPE |
DOUBLE FOCUS, ROTATING ANODE RADIOGRAPHIC |
| BNBB |
TABLE TYPE |
NONTILTING |
| BPKZ |
RECTIFICATION TYPE |
FULL-WAVE |
| CLPG |
TUBE COOLING METHOD |
AIR |
| CLPH |
TUBE MOUNTING TYPE |
TUBE STAND |
| CLPR |
TUBE STAND MOUNTING TYPE |
SPRING COUNTER-BALANCE |
| CLPX |
RADIOGRAPHIC TIMER TYPE |
EXPOSURE |
| CLQD |
TRANSFORMER RECTIFICATION METHOD |
SOLID STATE |
| CLQF |
TRANSFORMER OUTPUT CAPACITY |
250 MA AT 100 KV PEAK AND 200 MA AT 125 KV PEAK |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
X-RAY APP RAD MED MOBILE 250MA AT 100PKV 115-230 VOLT 50-60HZ AC |
| ELEC |
VOLTAGE IN VOLTS |
115.0 AND 230.0 |
| FAAZ |
PHASE |
SINGLE |
| FREQ |
FREQUENCY IN HERTZ |
50.0 OR 60.0 |
| SUPP |
SUPPLEMENTARY FEATURES |
C/O COLLIMETER,CONTROL UNIT,TABLE,TRANSFORMER,AND TUBE STAND |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| ZP01 |
|
Apr-01-1991 |
|
|
|
|
ZP |
ZP |
| Description: |
X-RAY MACHINE |
Originating Activity: |
KX |
| Hazardous Material: |
|
National Motor Freight Classification Number: |
063560 |
| Less Than One Truckload: |
W |
NMFC Sub-Item: |
Z |
| Uniform Freight Classification Number: |
98185 |
Rail Variance Code: |
|
| Less Than One Carload: |
|
Water Commodity Code: |
656 |
| Type of Cargo Code: |
Z |
Special Handling Code: |
9 |
| Air Commodity Special Handling Code: |
MZ |
Air Dimension Code: |
A |
| Source: |
P |
Primary Inventory Control Activity (PICA) |
Status: |
C |
| Pri/Sec ICC: |
P |
Container NSN: |
|
Category Code: |
|
| Lvl A Pkg Req: |
Z |
Unit Pack Size: |
|
Pres Material: |
ZZ |
| Lvl B Pkg Req: |
|
Unit Pack Weight: |
650.0 |
Pres Method: |
ZZ |
| Lvl C Pkg Req: |
|
Unit Pack Cube: |
38.000 |
Wrapping Mat: |
ZZ |
| Opt Proc Ind: |
M |
Unpkg Item Dims: |
|
Spec Marking: |
ZZ |
| Container FSC: |
|
SPI Number: |
MPPWN00001 |
SPI Revision: |
|
| Unpkg Weight: |
|
SPI Date: |
Mar-30-1988 |
Pkg Design Activity: |
|
| Inter Container Qty: |
|
Inter Container Code: |
|
Clean/Dry Procedure: |
Z |
| Unit Container: |
ZZ |
Item Type Storage: |
|
Unit Container Level: |
|
| |
|
Cush/Dun Material: |
ZZ |
Cush/Dun Thickness: |
Z |
|