National Stock Number(NSN): 6515-01-369-5849 (6515013695849, 013695849)
| NIIN: |
01-369-5849 |
Item Name: |
DRAINAGE AND MONITORING SYSTEM,EXTERNAL,CEREBROSPINAL FLUID |
INC: |
48922
|
| FSC: |
6515
|
Assignment Date: |
Dec-29-1992 |
CRIT: |
N |
IIG: |
48922 |
| ISC: |
5 |
Date Standardized: |
Dec-29-1992 |
HMIC: |
N |
DODIC: |
|
| NSC: |
4 |
Cancellation Date: |
Nov-19-2002 |
PMIC: |
A |
FIIG: |
T107-A |
| ESD: |
|
Schedule B: |
|
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
1 |
Originator: |
97 |
ADPEC: |
|
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
10-100 |
0VZE1
|
CLINICAL NEURO SYSTEMS INC CONNELL NEURO SURGICAL |
H |
3 |
2 |
4 |
KX |
|
|
|
|
|
|
|
10-100 |
66736
|
NAVAL MEDICAL MATERIAL SUPPORT COMMAND DETACHMENT |
H |
3 |
2 |
|
|
|
|
|
|
|
|
|
92-9-21-63 CC |
66736
|
NAVAL MEDICAL MATERIAL SUPPORT COMMAND DETACHMENT |
H |
5 |
1 |
4 |
KX |
|
|
|
|
|
|
|
MONITORR ICP EX CSF DRNG/MNTRG |
0VZE1
|
CLINICAL NEURO SYSTEMS INC CONNELL NEURO SURGICAL |
H |
5 |
1 |
4 |
KX |
|
|
|
|
|
|
|
MONITORR ICP EX CSF DRNG/MNTRG |
66736
|
NAVAL MEDICAL MATERIAL SUPPORT COMMAND DETACHMENT |
H |
5 |
1 |
|
|
|
|
|
|
|
|
|
N92I002 |
66736
|
NAVAL MEDICAL MATERIAL SUPPORT COMMAND DETACHMENT |
H |
5 |
1 |
4 |
KX |
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DA |
S9M |
L |
|
0 |
U |
1 |
A |
$85.00 |
EA |
|
C2203X- |
Mar-01-1993 |
H |
| DF |
JDC |
L |
|
0 |
U |
1 |
F |
$85.00 |
EA |
|
------- |
Jun-01-1995 |
H |
| DN |
JDC |
L |
|
0 |
U |
1 |
N |
$85.00 |
EA |
|
9L----- |
Mar-01-1993 |
H |
| DS |
JDC |
L |
|
0 |
U |
1 |
D |
$85.00 |
EA |
|
------- |
Dec-01-1992 |
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DA |
R |
REFER TO NOT DMSB STZD |
000 |
|
|
|
| DF |
R |
REFER TO NON-STD NON-DMSB REV |
000 |
|
|
|
| DS |
R |
REFER TO NON-STD NON-DMSB REV |
000 |
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ALPC |
COMPONENT AND QUANTITY |
BRAIDED CORD WITH CORD LOCK 1; ONE-WAY VALVE 1; RED END CAPS 2; MANIFOLD STOPCOCK 1; Y-INJECTION SITE 1; INJECTION SITES 3; PATIENT LINE STOPCOCK 1; PATIENT LINE W/GREEN STRIP 1; MICROBIAL FILTER VENT 1; TOP CAP OF CHAMBER W/VENT GUARD 1; DRIP FORMER 1; GRADUATED CHAMBER (100ML) 1; PANEL (WITH INSTRUCTION FOR USE) 1; CHAMBER STOCKSTOP 1; DRAINAGE BAG 1; CONNECTING TUBING |
| CBBL |
FEATURES PROVIDED |
DISPOSABLE AND STERILE |
| FEAT |
SPECIAL FEATURES |
CLOSED INTEGRAL SYSTEM; REQUIRES NO ASSEMBLY; DESIGNED FOR THE DRAINAGE OF CEREBROSPINAL FLUID AND ALLOWS FOR ACCURATE PRESSURE AND FLOW RATE MONITORING |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| A111 |
|
Dec-30-1992 |
0 |
0 |
|
|
|
|
| FSKX |
|
Dec-30-1992 |
0 |
0 |
|
|
|
|
| N9LM |
|
Dec-30-1992 |
0 |
0 |
|
|
|
|
|