National Stock Number(NSN): 6515-01-332-5785 (6515013325785, 013325785)
| NIIN: |
01-332-5785 |
Item Name: |
MANIFOLD ASSEMBLY,OXYGEN DELIVERY |
INC: |
47216
|
| FSC: |
6515
|
Assignment Date: |
Jan-12-1991 |
CRIT: |
X |
IIG: |
47216 |
| ISC: |
2 |
Date Standardized: |
Jan-12-1991 |
HMIC: |
N |
DODIC: |
|
| NSC: |
0 |
Cancellation Date: |
|
PMIC: |
A |
FIIG: |
A23800 |
| ESD: |
|
Schedule B: |
9018.90.8000 |
DEMIL: |
A |
DEMIL INT: |
1 |
| TIIC: |
4 |
Originator: |
KX |
ADPEC: |
|
RPDMRC: |
3 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
405 |
62002
|
LIFE SUPPORT PRODUCTS INC |
C |
3 |
9 |
4 |
KX |
|
|
|
|
|
|
|
405 |
62842
|
ALLIED HEALTHCARE PRODUCTS, INC. |
C |
3 |
2 |
4 |
ZZ |
|
|
|
|
|
|
|
90-0996 |
64616
|
DEFENSE MEDICAL STANDARDIZATION BOARD |
H |
5 |
1 |
4 |
KX |
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DA |
SMS |
Y |
|
0 |
U |
1 |
A |
$2,165.22 |
EA |
|
C2203N- |
Oct-01-2025 |
C |
| DF |
SMS |
Y |
|
0 |
U |
1 |
F |
$2,165.22 |
EA |
|
------- |
Oct-01-2025 |
C |
| DN |
SMS |
Y |
|
0 |
U |
1 |
N |
$2,165.22 |
EA |
|
9B----A |
Jan-01-2026 |
H |
| DS |
SMS |
Y |
|
0 |
U |
1 |
D |
$2,605.13 |
EA |
|
------- |
Oct-01-2022 |
H |
| DS |
SMS |
Y |
|
0 |
U |
1 |
I |
$2,165.22 |
EA |
|
------- |
Oct-01-2025 |
C |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DN |
V |
DISCONTINUED WITHOUT REPLACEMENT |
000 |
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| AJJW |
COMPONENT QUANTITY |
20 |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
MANIFOLD ASSY OXY DELIVERY W/HUMIDIFIERS & MULTI OUTLETS IN CASE |
| FEAT |
SPECIAL FEATURES |
WITH HUMIDIFIERS AND MULTIPLE OUTLETS; HOUSED IN A SEMIRIGID CASE,13 IN. HIGH; 19-3/4 IN. WIDE; 13 IN. DEEP; FOR SIMULTANEOUS ADMINISTRATION OF LOW FLOW,HUMIDIFIED OXYGEN FROM ONE TO AS MANY AS EIGHT PATIENTS AND PROVIDES OXYGEN FOR ONE MEDICAL DEVICE REQUIRING NOMINAL 50 PSIG OXYGEN SUPPLY,ALL FROM ONE CYLINDER WITH AN OXYGEN REGULATOR; CONSISTS OF HOSE,OXYGEN SUPPLY,APPROX. 10 FT (3.05 METERS) 1; HUMIDIFER 8; MASK,OXYGEN,TRANSPORT TYPE,ADULT SIZE,SINGLE USE WITH 7 FT (2.13 METER) OXYGEN TUBING EACH 8; NINE OUTLET MANIFOLD WITH ANODIZED ALUMINUM BODY WITH EIGHT CONSTANT FLOW SELECTOR VALVES WITH FLOW RATES OF 2,4,6 10 AND 15 LPM AND ONE STANDARD MALE OXYGEN DISS CHECK VALVE FITTING 1; STAND,ALUMINUM,ATTACHED TO MANIFOLD TO SUPPORT MANIFOLD WITH OUTLETS ON HORIZONTAL SIDES OF MANIFOLD 2 |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| A911 |
A111 |
Dec-01-2006 |
3 |
Z |
|
|
AM|GX |
AM|BN|GX |
| FSGM |
FSKX |
Dec-01-2006 |
3 |
Z |
|
|
GX|TT |
GX|SS|TT |
| Description: |
MEDICAL TREATMENT NOI |
Originating Activity: |
KX |
| Hazardous Material: |
|
National Motor Freight Classification Number: |
056590 |
| Less Than One Truckload: |
W |
NMFC Sub-Item: |
Z |
| Uniform Freight Classification Number: |
00000 |
Rail Variance Code: |
|
| Less Than One Carload: |
|
Water Commodity Code: |
651 |
| Type of Cargo Code: |
Z |
Special Handling Code: |
9 |
| Air Commodity Special Handling Code: |
MZ |
Air Dimension Code: |
A |
| Source: |
P |
Primary Inventory Control Activity (PICA) |
Status: |
C |
| Pri/Sec ICC: |
P |
Container NSN: |
|
Category Code: |
ZZZZ |
| Lvl A Pkg Req: |
Z |
Unit Pack Size: |
|
Pres Material: |
ZZ |
| Lvl B Pkg Req: |
|
Unit Pack Weight: |
0.0 |
Pres Method: |
ZZ |
| Lvl C Pkg Req: |
|
Unit Pack Cube: |
0.000 |
Wrapping Mat: |
ZZ |
| Opt Proc Ind: |
M |
Unpkg Item Dims: |
|
Spec Marking: |
ZZ |
| Container FSC: |
|
SPI Number: |
MPPWN00001 |
SPI Revision: |
|
| Unpkg Weight: |
|
SPI Date: |
Mar-30-1988 |
Pkg Design Activity: |
89875
|
| Inter Container Qty: |
|
Inter Container Code: |
|
Clean/Dry Procedure: |
Z |
| Unit Container: |
ZZ |
Item Type Storage: |
|
Unit Container Level: |
|
| |
|
Cush/Dun Material: |
ZZ |
Cush/Dun Thickness: |
Z |
|