National Stock Number(NSN): 6515-01-304-6505 (6515013046505, 013046505)
| NIIN: |
01-304-6505 |
Item Name: |
DEFIBRILLATOR AND CARDIOSCOPE |
INC: |
35185
|
| FSC: |
6515
|
Assignment Date: |
|
CRIT: |
|
IIG: |
35185 |
| ISC: |
2 |
Date Standardized: |
|
HMIC: |
|
DODIC: |
|
| NSC: |
8 |
Cancellation Date: |
May-17-1997 |
PMIC: |
A |
FIIG: |
A23900 |
| ESD: |
|
Schedule B: |
|
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
4 |
Originator: |
|
ADPEC: |
|
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
K-050 |
64616
|
DEFENSE MEDICAL STANDARDIZATION BOARD |
H |
5 |
1 |
|
|
|
|
|
|
|
|
|
LP6S |
3U903
|
PHYSIO-CONTROL CORP MID-ATLANTIC DISTRICT SALES AND SERVICE OFFICE |
H |
3 |
2 |
|
|
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DN |
S9M |
Y |
|
0 |
|
1 |
|
$3,052.45 |
EA |
|
9L----- |
|
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DN |
V |
Discontinued without Replacement |
|
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| FTLD |
FUNCTIONAL DESCRIPTION |
CENTRAL PROCUREMENT OF MEDICAL EQUIPMENT "CENPROME"SERVICE CONTROLLED AND MANAGED ITEM;REQUISITION USING PUBLISHED CUSTOMER ORDER LIST (COL)ONLY IN ACCORDANCE WITH SERVICE OR AGENCY INSTRUCTIONS;SERVICE POINTS OF CONTACT FOR INFORMATION AND REQUISITIONING INSTRUCTIONS ARE:U. S. ARMY MEDICAL MATERIEL AGENCY,USAMMA/SGMMA-OM,FT DETRICK,MD 21701,AV 343-7487 COMM (301)663-7403;AIR FORCE MEDICAL LOGISTICS OFFICE,AFMLO/FOM,FT DETRICK MD 21701,AV 343-7487 COMM (301)663-7487;NAVAL MEDICAL MATERIEL SUPPORT COMMAND,NAVMEDMATSUPCOM,FT DETRICK MD 21701,AV 343-7117 COMM (301)663-7117;CONTRACT DLA 120-88-D-8184;REQUISITIONER SHOULD SPECIFY VOLTAGE AND FREQUENCY REQUIRED;115 VAC 60 HZ;115 VAC,50 HZ;230 VAC,50 HZ;230 VAC,60 HZ |
| NTRD |
ENTRY DATE |
89-07-26 |
| TEXT |
GENERAL CHARACTERISTICS ITEM DESCRIPTION |
117/220 VOLT,50/60 HZ,AC OR 12 VOLT DC;WITH INTEGRAL BATTERY CHARGER;SEPERABLE MODULAR UNIT;5-360 JOULES MONOPHASIC DC OUTPUT;12 LEAD DIAGNOSTIC MONITORING WITH SYNCHRONOUS CARDIOVERSION;8-1/4 BY 11 BY 19 IN. (20.9 BY 27.9 BY 48.3 CM);16 HOUR CHARGETIME;PROVIDES FOUR HOURS OF MONITORING OR ONE HOUR OF RECORDING;CONTINUOUS NON-FADE TRACE,FREEZE CONTROL AND 12 LEAD ECG;HIGH AND LOW HEART RATE ALARM;INCLUDES TWO FIVE-LEAD PATIENT CABLES WITH FEMALE SNAP-TYPE CONTACT,THREE ROLLS ECG PAPER,ONE ELECTRODE ACCESSORY KIT CONTAINING FOUR LIMB ELECTRODES,30 MM WELSH SUCTION CUP,15 MM WELSH SUCTION CUP,FOUR 40 CM ADULT LIMB STRAPS,A FIVE-LEAD PATIENT CABLE,SIX PIN CONNECTOR WITH PIN ENDS FOR METAL ELECTRODES,ONE PAIR PEDIATRIC PADDLES,ONE PAIR EXTERNAL ADULT PADDLES,18 MM SUCTION CUP ELECTRODE,SPARE STYLUS,STYLUS INSERTION TOOL,ECG RULER,12 PRE-GELLED ELECTRODES,ELECTRODE JELLY AND ONE ACCESSORY BAG;FOR CLINICAL OR HOSPITAL USE |
|