| MRC |
Requirement Statement |
Reply Statement |
| AAGR |
CROSS-SECTIONAL SHAPE STYLE |
6 ROUND |
| ABJH |
TEMP RATING |
125.0 CELSIUS |
| ABKV |
OUTSIDE DIAMETER |
0.720 INCHES NOMINAL SINGLE CONDUCTOR |
| ADVL |
CROSS SECTION OUTSIDE DIAMETER |
0.102 INCHES MINIMUM AND 0.110 INCHES MAXIMUM |
| BLNZ |
STRAND QUANTITY PER CONDUCTOR |
19 SINGLE CONDUCTOR |
| CXCW |
CONDUCTOR FORM |
STRANDED SINGLE CONDUCTOR |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
WIRE, ELECTRICAL, CROSSLINKED, MODIFIED POLYETHYLENE(XPLE) INSULATED 125 DEG CELCIUS, 1000 VOLTS |
| CXDC |
ROUND CONDUCTOR SIZE |
14 AWG SINGLE CONDUCTOR |
| CXDG |
STRAND AWG SIZE PER CONDUCTOR |
27 SINGLE CONDUCTOR |
| CXDM |
CONDUCTOR CROSS-SECTIONAL SHAPE |
TUBULAR BRAID SINGLE CONDUCTOR |
| CXFK |
VOLTAGE RATING |
1000.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR |
| HUES |
COLOR |
BLACK FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR |
| MATT |
MATERIAL |
COPPER CORE CONDUCTOR SINGLE CONDUCTOR |
| MATT |
MATERIAL |
PLASTIC CROSS LINKED POLYETHYLENE FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR |
| MDCL |
MATERIAL DOCUMENT AND CLASSIFICATION |
ASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR |
| SFTT |
SURFACE TREATMENT |
TIN CORE CONDUCTOR SINGLE CONDUCTOR |
| STDC |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION |
ASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-DTL-16878/15 GOVERNMENT SPECIFICATION |