| MRC |
Requirement Statement |
Reply Statement |
| ABHP |
OVERALL LENGTH |
19.000 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
5.250 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
13.110 INCHES NOMINAL |
| AGAV |
END ITEM IDENTIFICATION |
F-15 |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| ANPM |
INPUT PHASE |
SINGLE FIRST ALTERNATE OPERATING POWER RQMT |
| ANPM |
INPUT PHASE |
SINGLE SECOND ALTERNATE OPERATING POWER RQMT |
| ANPM |
INPUT PHASE |
SINGLE THIRD ALTERNATE OPERATING POWER RQMT |
| ANPM |
INPUT PHASE |
SINGLE FOURTH ALTERNATE OPERATING POWER RQMT |
| APNX |
INPUT VOLTAGE RATING |
90.0 AC VOLTS MINIMUM AND 110.0 AC VOLTS MAXIMUM FIRST ALTERNATE OPERATING POWER RQMT |
| APNX |
INPUT VOLTAGE RATING |
120.0 AC VOLTS MINIMUM AND 130.0 AC VOLTS MAXIMUM SECOND ALTERNATE OPERATING POWER RQMT |
| APNX |
INPUT VOLTAGE RATING |
220.0 AC VOLTS MINIMUM AND 230.0 AC VOLTS MAXIMUM THIRD ALTERNATE OPERATING POWER RQMT |
| APNX |
INPUT VOLTAGE RATING |
230.0 AC VOLTS MINIMUM AND 250.0 AC VOLTS MAXIMUM FOURTH ALTERNATE OPERATING POWER RQMT |
| APPA |
OUTPUT VOLTAGE RATING |
0.0 DC KILOVOLTS MINIMUM AND 30.0 DC KILOVOLTS MAXIMUM SINGLE POWER OUTPUT |
| APTQ |
INPUT FREQUENCY RATING |
48.0 HERTZ MINIMUM AND 62.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
| APTQ |
INPUT FREQUENCY RATING |
48.0 HERTZ MINIMUM AND 62.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
| APTQ |
INPUT FREQUENCY RATING |
48.0 HERTZ MINIMUM AND 62.0 HERTZ MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT |
| APTQ |
INPUT FREQUENCY RATING |
48.0 HERTZ MINIMUM AND 62.0 HERTZ MAXIMUM 4TH ALTERNATE OPERATING POWER RQMT |
| AYNH |
OPERATING AMBIENT TEMP RANGE |
0.1 TO 50.0 CELSIUS |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |
| CWGH |
OUTPUT CURRENT RATING |
0.0 DC MILLIAMPERES MINIMUM AND 1.5 DC MILLIAMPERES MAXIMUM SINGLE POWER OUTPUT |
| CWHC |
OUTPUT CONTROL LOCATION |
REAR PANEL SINGLE POWER OUTPUT |
| CWHF |
OUTPUT CONNECTION QUANTITY |
1 SINGLE POWER OUTPUT |
| CWHJ |
OUTPUT CONNECTION TYPE |
CONNECTOR, RECEPTACLE SINGLE POWER OUTPUT |
| CWHM |
INPUT CURRENT RATING |
70.0 AC AMPERES NOMINAL FIRST ALTERNATE OPERATING POWER RQMT |
| CWHM |
INPUT CURRENT RATING |
70.0 AC AMPERES NOMINAL SECOND ALTERNATE OPERATING POWER RQMT |
| CWHM |
INPUT CURRENT RATING |
70.0 AC AMPERES NOMINAL THIRD ALTERNATE OPERATING POWER RQMT |
| CWHM |
INPUT CURRENT RATING |
70.0 AC AMPERES NOMINAL FOURTH ALTERNATE OPERATING POWER RQMT |
| CWHT |
INPUT CONNECTION QUANTITY |
1 FIRST ALTERNATE OPERATING POWER RQMT |
| CWHT |
INPUT CONNECTION QUANTITY |
1 SECOND ALTERNATE OPERATING POWER RQMT |
| CWHT |
INPUT CONNECTION QUANTITY |
1 THIRD ALTERNATE OPERATING POWER RQMT |
| CWHT |
INPUT CONNECTION QUANTITY |
1 FOURTH ALTERNATE OPERATING POWER RQMT |
| CWKG |
VENTILATION DESIGN TYPE |
CONVECTION |
| FEAT |
SPECIAL FEATURES |
OUTPUT VOLTAGE ANALOG METER, CONTROL SELECTOR SWITCH, VOLTAGE AND CURRENT ADJUSTABLE, LOCAL CONTROL POTENTIOMETER, ELECTROSTATIC SENSITIVE DEVICE |