| MRC |
Requirement Statement |
Reply Statement |
| AGAV |
END ITEM IDENTIFICATION |
MILSTAR USED ON: AN/ASC-21 |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| ANPM |
INPUT PHASE |
THREE 1ST ALTERNATE OPERATING POWER RQMT |
| ANPM |
INPUT PHASE |
THREE 2ND ALTERNATE OPERATING POWER RQMT |
| APNX |
INPUT VOLTAGE RATING |
115.0 AC VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
| APNX |
INPUT VOLTAGE RATING |
200.0 AC VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
| APPA |
OUTPUT VOLTAGE RATING |
-15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
| APPA |
OUTPUT VOLTAGE RATING |
-3.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
| APPA |
OUTPUT VOLTAGE RATING |
5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
| APPA |
OUTPUT VOLTAGE RATING |
15.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
| APPA |
OUTPUT VOLTAGE RATING |
28.0 DC VOLTS NOMINAL 5TH POWER OUTPUT |
| APTQ |
INPUT FREQUENCY RATING |
400.0 HERTZ NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
| APTQ |
INPUT FREQUENCY RATING |
400.0 HERTZ NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
| CBBL |
FEATURES PROVIDED |
OVER VOLTAGE PROTECTOR AND OVER CURRENT PROTECTOR |
| CWGH |
OUTPUT CURRENT RATING |
1.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
| CWGH |
OUTPUT CURRENT RATING |
3.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
| CWGH |
OUTPUT CURRENT RATING |
2.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
| CWGH |
OUTPUT CURRENT RATING |
1.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
| CWGH |
OUTPUT CURRENT RATING |
3.5 DC AMPERES NOMINAL 6TH POWER OUTPUT |
| CWHM |
INPUT CURRENT RATING |
2.2 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
| CWHM |
INPUT CURRENT RATING |
2.2 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
| CWKG |
VENTILATION DESIGN TYPE |
CONVECTION |
| FEAT |
SPECIAL FEATURES |
POWER SUPPLY SRU 1 KW UHF SSHPA |
| ZZZY |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS |
AS DIFFERENTIATED BY SOURCE CONTRL REPAIR DRAWING NUMBER 861009 |