| MRC |
Requirement Statement |
Reply Statement |
| ABHP |
OVERALL LENGTH |
11.000 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
2.750 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
4.870 INCHES NOMINAL |
| AGAV |
END ITEM IDENTIFICATION |
C130H TEST SET 4920-01-120-6241 |
| AKWC |
ELECTRICAL POWER SOURCE RELATIONSHIP |
OPERATING |
| AMQY |
INSTALLATION DESIGN |
PANEL |
| ANPM |
INPUT PHASE |
SINGLE SINGLE OPERATING POWER RQMT |
| APNX |
INPUT VOLTAGE RATING |
207.0 AC VOLTS MINIMUM AND 253.0 AC VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
| APNX |
INPUT VOLTAGE RATING |
103.5 AC VOLTS MINIMUM AND 126.5 AC VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
| APPA |
OUTPUT VOLTAGE RATING |
12.0 DC VOLTS MINIMUM AND 15.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
| APPA |
OUTPUT VOLTAGE RATING |
12.0 DC VOLTS MINIMUM AND 15.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
| APPA |
OUTPUT VOLTAGE RATING |
5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
| APTQ |
INPUT FREQUENCY RATING |
50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| AYNH |
OPERATING AMBIENT TEMP RANGE |
-0.0 TO 50.0 CELSIUS |
| CBBL |
FEATURES PROVIDED |
OUTPUT TO CASE ISOLATION AND OVER VOLTAGE PROTECTOR AND REMOTE ERROR SENSING CAPABILITY AND VOLTAGE ADJUSTMENT |
| CWGH |
OUTPUT CURRENT RATING |
1.5 DC AMPERES MINIMUM AND 1.7 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
| CWGH |
OUTPUT CURRENT RATING |
1.5 DC AMPERES MINIMUM AND 1.7 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
| CWGH |
OUTPUT CURRENT RATING |
6.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
| CWHF |
OUTPUT CONNECTION QUANTITY |
4 SINGLE POWER OUTPUT |
| CWHJ |
OUTPUT CONNECTION TYPE |
SOLDER LUG SINGLE POWER OUTPUT |
| CWHQ |
INPUT CONNECTION TYPE |
SOLDER LUG SINGLE OPERATING POWER RQMT |
| CWHT |
INPUT CONNECTION QUANTITY |
2 SINGLE OPERATING POWER RQMT |
| CWKG |
VENTILATION DESIGN TYPE |
CONVECTION |
| CWWY |
POWER SUPPLY EFFICIENCY LINE |
45.0 |
| NHCF |
NUCLEAR HARDNESS CRITICAL FEATURE |
NONHARDENED |
| SUWT |
UNIT OF ISSUE WEIGHT |
8.00 POUNDS |