National Stock Number(NSN): 6110-01-503-8978 (6110015038978, 015038978)
| NIIN: |
01-503-8978 |
Item Name: |
CONTROLLER,MOTOR |
INC: |
00904
|
| FSC: |
6110
|
Assignment Date: |
Jan-13-2003 |
CRIT: |
X |
IIG: |
00904 |
| ISC: |
6 |
Date Standardized: |
Jan-15-2003 |
HMIC: |
N |
DODIC: |
|
| NSC: |
0 |
Cancellation Date: |
|
PMIC: |
U |
FIIG: |
A541B0 |
| ESD: |
|
Schedule B: |
8543.90.9000 |
DEMIL: |
A |
DEMIL INT: |
1 |
| TIIC: |
4 |
Originator: |
CX |
ADPEC: |
0 |
RPDMRC: |
3 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
215-007-010 REV C |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
C |
D |
9 |
2 |
ZZ |
|
|
|
|
|
|
|
PL215-007-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
C |
5 |
2 |
2 |
ZZ |
|
|
|
|
|
|
|
TYPE 3CC2 |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
C |
3 |
2 |
2 |
ZZ |
|
|
|
|
|
|
Additional Part Information
| Part Number |
CAGE |
Company |
Source |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
| 215-007-013 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-008-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-008-013 REV A |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-019-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-019-013 REV A |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-020-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-020-013 REV A |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-021-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-021-013 REV A |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-022-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-022-013 REV A |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-023-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-023-013 REV A |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-024-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| 215-024-013 REV A |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| PL215-008-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| PL215-019-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| PL215-020-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| PL215-021-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| PL215-022-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| PL215-023-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| PL215-024-010 REV B |
6Z538
|
CAROLINA POWER SYSTEMS OF SUMTER INC |
CRF,APL |
5 |
2 |
3 |
HD |
|
N |
0 |
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DN |
SMS |
J |
D |
0 |
U |
1 |
N |
$6,591.18 |
EA |
|
3B----- |
Oct-01-2025 |
C |
| DS |
SMS |
J |
F |
0 |
U |
1 |
D |
$7,229.51 |
EA |
|
------- |
Oct-01-2022 |
H |
| DS |
SMS |
J |
F |
0 |
U |
1 |
I |
$6,591.18 |
EA |
|
------- |
Oct-01-2025 |
C |
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ABHP |
OVERALL LENGTH |
22.120 INCHES MAXIMUM |
| ABKW |
OVERALL HEIGHT |
28.120 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
10.400 INCHES MAXIMUM |
| ACYN |
AC VOLTAGE RATING |
440.0 VOLTS NOMINAL |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL |
| AFLW |
ACTUATION METHOD |
MAGNETIC |
| AGAV |
END ITEM IDENTIFICATION |
MOTOR CONTROLLER SS-7 FAN MOTOR |
| AGUE |
FUSE ACCOMMODATION QUANTITY |
4 |
| AJXE |
SIZE DESIGNATOR |
2 |
| AKPS |
DUTY CYCLE |
CONTINUOUS |
| ANCN |
OPERATING VOLTAGE CHARACTERISTIC |
FULL |
| ANCY |
HORSEPOWER RATING |
25.000 |
| ANDG |
FUSE CURRENT RATING IN AMPS |
10.0 AND 5.0 |
| ANDX |
AMBIENT TEMP |
50.0 CELSIUS |
| ANPZ |
ENCLOSURE FEATURE |
DRIPPROOF |
| ANQC |
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN |
DESIGNED PER NEMA STD |
| AQZF |
CONTROL TYPE |
LOCAL OR REMOTE |
| CBBL |
FEATURES PROVIDED |
REVERSIBLE AND CIRCUIT PROTECTION FUSE |
| FAAZ |
PHASE |
THREE |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| N9BG |
N9GD |
Feb-01-2005 |
3 |
H |
Z |
HD |
GX|HD |
GH|GX |
Replacement & Obsolete Information
| FSC |
NICN |
Status |
|
LL-H59-1338 |
H |
| 0099 |
LL-H59-1338 |
H |
| Description: |
CONTROLLERS/PARTS NOI O/T PLASTIC |
Originating Activity: |
CX |
| Hazardous Material: |
|
National Motor Freight Classification Number: |
061480 |
| Less Than One Truckload: |
P |
NMFC Sub-Item: |
X |
| Uniform Freight Classification Number: |
34500 |
Rail Variance Code: |
|
| Less Than One Carload: |
|
Water Commodity Code: |
590 |
| Type of Cargo Code: |
Z |
Special Handling Code: |
9 |
| Air Commodity Special Handling Code: |
HZ |
Air Dimension Code: |
A |
|