National Stock Number(NSN): 6110-01-024-9918 (6110010249918, 010249918)
| NIIN: |
01-024-9918 |
Item Name: |
CONTACTOR,MAGNETIC |
INC: |
31517
|
| FSC: |
6110
|
Assignment Date: |
Jul-23-1976 |
CRIT: |
N |
IIG: |
31517 |
| ISC: |
2 |
Date Standardized: |
Oct-26-1990 |
HMIC: |
N |
DODIC: |
|
| NSC: |
4 |
Cancellation Date: |
Jul-06-2000 |
PMIC: |
U |
FIIG: |
T173-B |
| ESD: |
|
Schedule B: |
|
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
K |
Originator: |
CX |
ADPEC: |
|
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
CA1-60 240V |
52034
|
SPRECHER AND SCHUH INC S AND S CONTROLS DIV |
H |
C |
1 |
5 |
48 |
|
|
|
AH |
|
|
|
CA1-60-240-NO |
3B242
|
HUNZICKER BROTHERS INC |
H |
5 |
2 |
5 |
48 |
|
|
|
|
|
|
|
CA1-60-240-NO |
52034
|
SPRECHER AND SCHUH INC S AND S CONTROLS DIV |
H |
3 |
2 |
5 |
48 |
|
|
|
|
|
|
|
CA1-60-2P240V |
52034
|
SPRECHER AND SCHUH INC S AND S CONTROLS DIV |
H |
C |
1 |
5 |
48 |
|
|
|
AH |
|
|
|
S108-0055 |
93742
|
DRS NAVAL POWER SYSTEMS INC |
H |
5 |
2 |
5 |
48 |
1 |
A |
|
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ABBB |
SPEED ADJUSTMENTS |
SINGLE SPEED |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
ANY ACCEPTABLE |
| ABHP |
OVERALL LENGTH |
8.750 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
5.500 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
5.875 INCHES NOMINAL |
| ACYN |
AC VOLTAGE RATING |
208.0 VOLTS MINIMUM AND 440.0 VOLTS MAXIMUM |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL |
| AFLW |
ACTUATION METHOD |
MAGNETIC |
| AGLD |
PERFORMANCE TYPE |
ANY ACCEPTABLE |
| AJNC |
REVERSIBLE FEATURE |
NOT INCLUDED |
| AJXE |
SIZE DESIGNATOR |
3 |
| AKPS |
DUTY CYCLE |
CONTINUOUS |
| ALGC |
MOUNTING CONFIGURATION |
FOUR 0.250 IN. DIA MTG HOLES ON 5.875 IN. BY 5.250 IN. MTG CTRS |
| ANCN |
OPERATING VOLTAGE CHARACTERISTIC |
FULL |
| ANCX |
CONTROL TYPE |
REMOTE |
| ANCY |
HORSEPOWER RATING |
25.000 AND 50.000 |
| ANDE |
ACTUATOR VOLTAGE |
220.0 AC AND 240.0 AC |
| ANDW |
LOAD PROTECTION TYPE |
ANY ACCEPTABLE |
| ANDX |
AMBIENT TEMP |
NOT RATED |
| ANEF |
ACCESSORY |
NOT INCLUDED |
| ANPZ |
ENCLOSURE FEATURE |
OPEN |
| ANQC |
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN |
DESIGNED PER NEMA STD |
| ANRH |
AMP SIZE RATING |
110.0 |
| FAAZ |
PHASE |
THREE |
| FREQ |
FREQUENCY IN HERTZ |
50.0 AND 60.0 |
| FUSE |
CIRCUIT PROTECTION FUSE |
NOT PROVIDED |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| B480 |
|
Apr-01-1991 |
0 |
0 |
|
|
48 |
48 |
|