National Stock Number(NSN): 6110-00-410-3324 (6110004103324, 004103324)
| NIIN: |
00-410-3324⛔ |
Item Name: |
STARTER,MOTOR |
INC: |
77777 |
| FSC: |
6110
|
Assignment Date: |
|
CRIT: |
|
IIG: |
77777 |
| ISC: |
3 |
Date Standardized: |
|
HMIC: |
|
DODIC: |
|
| NSC: |
5 |
Cancellation Date: |
Mar-01-1995 |
PMIC: |
0 |
FIIG: |
|
| ESD: |
|
Schedule B: |
|
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
2 |
Originator: |
|
ADPEC: |
9 |
RPDMRC: |
|
| NIIN: |
00-174-1011 |
Item Name: |
STARTER,MOTOR |
| FSC: |
6110 |
Replacement Date: |
Mar-01-1995 |
|
INC: |
00905 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
675-504-9005 |
99193
|
HONEYWELL INTERNATIONAL INC. |
H |
5 |
9 |
|
|
|
|
|
|
|
|
|
675-504-9005 |
9AA11
|
GARRETT ENGINE DIV ALLIED-SIGNAL INC DBA ALLIED-SIGNAL AEROSPACE CO |
H |
5 |
2 |
|
|
|
|
|
|
|
|
|
85360BA01-110V60 |
07442
|
SQUARE D CO DALLAS ASSEMBLY PLANT |
H |
3 |
2 |
|
|
|
|
|
|
|
|
|
85360BA01-110V60 |
95271
|
SQUARE D CO LOS ANGELES ASSEMBLY PLANT |
H |
5 |
9 |
|
|
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DF |
S9G |
V |
N |
0 |
|
1 |
|
$66.27 |
EA |
|
SF9---V |
|
H |
| DS |
S9G |
Y |
|
0 |
|
1 |
|
$66.27 |
EA |
|
------- |
|
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DF |
F |
6110001741011 |
|
|
|
|
| DS |
Z |
6110001741011 |
|
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ABHP |
OVERALL LENGTH |
10.000 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
5.562 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
6.000 INCHES NOMINAL |
| ACYN |
AC VOLTAGE RATING |
115.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL |
| AFLW |
ACTUATION METHOD |
MAGNETIC |
| AGLD |
PERFORMANCE TYPE |
MANUAL |
| AJXE |
SIZE DESIGNATOR |
0 |
| AKPS |
DUTY CYCLE |
CONTINUOUS |
| ALGC |
MOUNTING CONFIGURATION |
THREE NO. 10-32 MTG SCREWS IRREGULARLY SPACED |
| ANCN |
OPERATING VOLTAGE CHARACTERISTIC |
FULL |
| ANCX |
CONTROL TYPE |
LOCAL |
| ANCY |
HORSEPOWER RATING |
1.000 |
| ANDE |
ACTUATOR VOLTAGE |
110.0 AC |
| ANDW |
LOAD PROTECTION TYPE |
OVERLOAD |
| ANDX |
AMBIENT TEMP |
NOT RATED |
| ANPZ |
ENCLOSURE FEATURE |
NOT RATED |
| ANQC |
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN |
DESIGNED PER NEMA STD |
| ANRK |
SWITCH FUNCTIONAL POSITIONS |
MASTER SWITCH MARKED START-STOP |
| FAAZ |
PHASE |
SINGLE |
| FREQ |
FREQUENCY IN HERTZ |
60.0 |
| FUSE |
CIRCUIT PROTECTION FUSE |
NOT PROVIDED |