|
National Stock Number(NSN): 5985-01-341-2156 (5985013412156, 013412156)
| NIIN: |
01-341-2156 |
Item Name: |
SWITCH,RADIO FREQUENCY TRANSMISSION LINE |
INC: |
05298
|
| FSC: |
5985
|
Assignment Date: |
Jun-26-1991 |
CRIT: |
X |
IIG: |
05298 |
| ISC: |
6 |
Date Standardized: |
Jun-29-1991 |
HMIC: |
P |
DODIC: |
|
| NSC: |
0 |
Cancellation Date: |
|
PMIC: |
A |
FIIG: |
A158A0 |
| ESD: |
|
Schedule B: |
8529.10.9000 |
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
4 |
Originator: |
TX |
ADPEC: |
|
RPDMRC: |
3 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
290099P9 |
94117
|
BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC. |
C |
3 |
2 |
A |
TX |
|
|
|
|
|
|
|
8031-D0-A5D-4C2-SN |
60583
|
STELLANT SYSTEMS INC |
C |
5 |
9 |
5 |
TX |
|
B |
|
|
|
|
|
8031-D0-A5D-4C2-SN |
99899
|
NARDA HOLDINGS, INC. |
C |
5 |
2 |
5 |
TX |
|
|
|
|
|
|
|
8031-D0-A5D-4C2-SN |
28979
|
LORAL MICROWAVE-WAVECOM SUB OF LORAL CORP |
H |
5 |
9 |
5 |
TX |
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DF |
SMS |
J |
N |
0 |
U |
1 |
F |
$2,232.83 |
EA |
|
SF9EH-N |
Oct-01-2025 |
C |
| DS |
SMS |
J |
N |
0 |
U |
1 |
D |
$2,449.07 |
EA |
|
------- |
Oct-01-2022 |
H |
| DS |
SMS |
J |
N |
0 |
U |
1 |
I |
$2,232.83 |
EA |
|
------- |
Oct-01-2025 |
C |
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| AAQL |
BODY STYLE |
29B IRREGULAR |
| ABHP |
OVERALL LENGTH |
2.430 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
1.750 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
1.750 INCHES NOMINAL |
| ACZB |
FREQUENCY RATING |
0.0 GIGAHERTZ MINIMUM AND 6.0 GIGAHERTZ MAXIMUM FIRST FREQUENCY VOLTAGE STANDING WAVE RATIO |
| ACZB |
FREQUENCY RATING |
0.0 GIGAHERTZ MINIMUM AND 6.0 GIGAHERTZ MAXIMUM FIRST FREQUENCY INSERTION LOSS REFERENCE |
| ACZB |
FREQUENCY RATING |
6.0 GIGAHERTZ MINIMUM AND 12.0 GIGAHERTZ MAXIMUM SECOND FREQUENCY VOLTAGE STANDING WAVE RATIO |
| ACZB |
FREQUENCY RATING |
6.0 GIGAHERTZ MINIMUM AND 12.0 GIGAHERTZ MAXIMUM SECOND FREQUENCY INSERTION LOSS REFERENCE |
| ACZB |
FREQUENCY RATING |
12.0 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM THIRD FREQUENCY VOLTAGE STANDING WAVE RATIO |
| ACZB |
FREQUENCY RATING |
12.0 GIGAHERTZ MINIMUM AND 18.0 GIGAHERTZ MAXIMUM THIRD FREQUENCY INSERTION LOSS REFERENCE |
| AEEA |
SWITCH TYPE |
NONTRANSFER |
| AFGA |
OPERATING TEMP RANGE |
-40.0 TO 85.0 CELSIUS |
| AHUC |
COAXIAL CONNECTOR SERIES DESIGNATION |
SMA |
| AHUD |
CONNECTOR END DESIGN |
FEMALE |
| AKPN |
SWITCH OPERATION SEQUENCE |
BREAKS BEFORE MAKES |
| AKPP |
SWITCHING TIME |
20.0 MILLISECONDS |
| AKPQ |
SWITCH RETURN MECHANISM TYPE |
FAIL-SAFE |
| AKPX |
POLE QUANTITY |
1 |
| AKPY |
THROW QUANTITY |
3 |
| AKRC |
COUPLING POSITION QUANTITY |
4 |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| FXGX |
FXTX |
Jul-01-2005 |
1 |
R |
Z |
SX |
GX|TU |
GX|TU |
| Description: |
COILS/YOKES FOCUS/DEFLECTION TV |
Originating Activity: |
TH |
| Hazardous Material: |
|
National Motor Freight Classification Number: |
061360 |
| Less Than One Truckload: |
M |
NMFC Sub-Item: |
X |
| Uniform Freight Classification Number: |
34430 |
Rail Variance Code: |
|
| Less Than One Carload: |
|
Water Commodity Code: |
72D |
| Type of Cargo Code: |
Z |
Special Handling Code: |
9 |
| Air Commodity Special Handling Code: |
HZ |
Air Dimension Code: |
A |
| Source: |
P |
Primary Inventory Control Activity (PICA) |
Status: |
C |
| Pri/Sec ICC: |
P |
Container NSN: |
|
Category Code: |
69F0 |
| Lvl A Pkg Req: |
Q |
Unit Pack Size: |
|
Pres Material: |
00 |
| Lvl B Pkg Req: |
Q |
Unit Pack Weight: |
1.0 |
Pres Method: |
41 |
| Lvl C Pkg Req: |
U |
Unit Pack Cube: |
0.072 |
Wrapping Mat: |
00 |
| Opt Proc Ind: |
O |
Unpkg Item Dims: |
|
Spec Marking: |
00 |
| Container FSC: |
|
SPI Number: |
|
SPI Revision: |
|
| Unpkg Weight: |
|
SPI Date: |
|
Pkg Design Activity: |
14933
|
| Inter Container Qty: |
AAA |
Inter Container Code: |
DO |
Clean/Dry Procedure: |
1 |
| Unit Container: |
EC |
Item Type Storage: |
B |
Unit Container Level: |
|
| |
|
Cush/Dun Material: |
NA |
Cush/Dun Thickness: |
C |
|