| MRC |
Requirement Statement |
Reply Statement |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.240 INCHES MINIMUM AND 2.260 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.140 INCHES MINIMUM AND 1.160 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABTB |
MOUNTING HOLE DIAMETER |
0.134 INCHES MINIMUM AND 0.139 INCHES MAXIMUM SINGLE GROUP |
| ACZB |
FREQUENCY RATING |
100.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ADAQ |
BODY LENGTH |
2.470 INCHES MINIMUM AND 2.530 INCHES MAXIMUM |
| ADAT |
BODY WIDTH |
1.370 INCHES MINIMUM AND 1.430 INCHES MAXIMUM |
| ADAU |
BODY HEIGHT |
0.610 INCHES MAXIMUM |
| AEHZ |
MAXIMUM OPERATING TEMP |
125.0 CELSIUS |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 |
| AXGY |
MOUNTING METHOD |
UNTHREADED HOLE(S) SINGLE GROUP |
| BPLC |
WINDING FUNCTION AND QUANTITY |
2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| CBBL |
FEATURES PROVIDED |
W/RECTIFIER |
| CQLC |
WINDING TAP LOCATION |
CENTER TAP SINGLE COMPONENT 1ST PRIMARY |
| CQLC |
WINDING TAP LOCATION |
CENTER TAP SINGLE COMPONENT ALL SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
4.5 AMPERES DC MAXIMUM |
| CRBZ |
WINDING OPERATING CURRENT |
300.0 MILLIAMPERES DC MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
5.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
14.50 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| FEAT |
SPECIAL FEATURES |
TERMINALS 6 AND 7 ON FIRST SECONDARY ARE TIED TOGETHER |
| PKWT |
UNPACKAGED UNIT WEIGHT |
120.0 GRAMS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
12 PIN |