| MRC |
Requirement Statement |
Reply Statement |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABHP |
OVERALL LENGTH |
3.062 INCHES NOMINAL |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.297 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.859 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW |
OVERALL HEIGHT |
4.750 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
3.062 INCHES NOMINAL |
| ACZB |
FREQUENCY RATING |
380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| ACZD |
TRANSFORMER WINDING CONNECTION TYPE |
WYE-WYE |
| ACZX |
WINDING SHIELDING METHOD |
CORE GROUNDED AND BROUGHT OUT TO TERMINAL AND INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| ADAT |
BODY WIDTH |
2.625 INCHES NOMINAL |
| ADAU |
BODY HEIGHT |
4.250 INCHES NOMINAL |
| AEHZ |
MAXIMUM OPERATING TEMP |
130.0 CELSIUS |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| AXGY |
MOUNTING METHOD |
THREADED STUD(S) SINGLE GROUP |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| CMLP |
THREAD QUANTITY PER INCH |
32 SINGLE GROUP |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
1.0 AMPERES DC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
230.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
185.00 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
203.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| THSD |
THREAD SERIES DESIGNATOR |
UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| TTQY |
TERMINAL TYPE AND QUANTITY |
12 SOLDER STUD |