National Stock Number(NSN): 5950-00-646-3397 (5950006463397, 006463397)
| NIIN: |
00-646-3397 |
Item Name: |
TRANSFORMER,POWER |
INC: |
32496
|
| FSC: |
5950
|
Assignment Date: |
Jan-01-1963 |
CRIT: |
X |
IIG: |
32496 |
| ISC: |
6 |
Date Standardized: |
Mar-21-1968 |
HMIC: |
P |
DODIC: |
|
| NSC: |
0 |
Cancellation Date: |
|
PMIC: |
U |
FIIG: |
A058B0 |
| ESD: |
|
Schedule B: |
|
DEMIL: |
A |
DEMIL INT: |
1 |
| TIIC: |
1 |
Originator: |
TX |
ADPEC: |
|
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
21855A |
04655
|
GENERAL DYNAMICS MISSION SYSTEMS, INC. |
C |
3 |
2 |
5 |
TX |
3 |
D |
|
|
|
|
|
575605 |
97315
|
BALLASTRAN CORP |
C |
5 |
9 |
5 |
TX |
3 |
B |
|
|
|
|
|
57605 |
57733
|
STEWART-WARNER CORPORATION |
C |
5 |
9 |
5 |
TX |
3 |
B |
|
|
|
|
|
C10085 |
72149
|
ELECTRONIC TRANSFORMER CORP |
C |
5 |
2 |
5 |
ZZ |
|
|
|
|
|
|
|
C2945-27 |
15280
|
NORTHROP GRUMMAN SYSTEMS CORPORATION |
C |
5 |
9 |
5 |
TX |
|
B |
|
|
|
|
|
C2945-27 |
26916
|
NORTHROP GRUMMAN SYSTEMS CORPORATION |
C |
5 |
2 |
5 |
ZZ |
|
|
|
|
|
|
|
P1-14329 |
53854
|
MAGNESPEC INC |
C |
5 |
2 |
5 |
ZZ |
|
|
|
|
|
|
|
P1-14329 |
95970
|
MTE CORP MILWAUKEE TRANSFORMER CO |
C |
5 |
9 |
X |
XX |
3 |
D |
|
|
|
|
|
C2945-27 |
05828
|
LITTON SYSTEMS INC APPLIED TECHNOLOGY DIV GOVERNMENT SYSTEMS |
H |
5 |
9 |
5 |
TX |
3 |
D |
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DF |
SMS |
J |
N |
0 |
U |
1 |
F |
$563.25 |
EA |
|
SF9EH-N |
Oct-01-2025 |
C |
| DN |
SMS |
V |
|
0 |
U |
1 |
N |
$496.86 |
EA |
|
9B--00- |
Oct-01-2016 |
H |
| DS |
SMS |
J |
N |
0 |
U |
1 |
D |
$617.80 |
EA |
|
------- |
Oct-01-2022 |
H |
| DS |
SMS |
J |
N |
0 |
U |
1 |
I |
$563.25 |
EA |
|
------- |
Oct-01-2025 |
C |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DN |
V |
DISCONTINUED W/O REPLACEMENT |
000 |
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ACZB |
FREQUENCY RATING |
310.0 HERTZ MINIMUM AND 1.76 KILOHERTZ MAXIMUM SINGLE COMPONENT |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ADAQ |
BODY LENGTH |
2.250 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
2.125 INCHES NOMINAL |
| ADAU |
BODY HEIGHT |
2.250 INCHES NOMINAL |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AKPV |
MOUNTING FACILITY QUANTITY |
2 SINGLE GROUP |
| AXGY |
MOUNTING METHOD |
THREADED STUD(S) SINGLE GROUP |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| CMLP |
THREAD QUANTITY PER INCH |
32 SINGLE GROUP |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
45.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT FIRST SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
4.0 AMPERES AC MAXIMUM SINGLE COMPONENT SECOND SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
480.00 AC VOLTS NOMINAL SINGLE COMPONENT FIRST SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
6.30 AC VOLTS NOMINAL SINGLE COMPONENT SECOND SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| THSD |
THREAD SERIES DESIGNATOR |
UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| TTQY |
TERMINAL TYPE AND QUANTITY |
7 TAB, SOLDER LUG |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| FXGX |
FXTX |
Jun-01-2006 |
1 |
L |
Z |
SX |
GX|TU |
GX|TU |
| YB01 |
|
Apr-01-1991 |
|
|
|
|
YB |
YB |
| YJ01 |
|
Apr-01-1991 |
|
|
|
|
YJ |
YJ |
| ZC01 |
|
Apr-01-1991 |
|
|
|
|
ZC |
ZC |
| ZP01 |
|
Apr-01-1991 |
|
|
|
|
ZP |
ZP |
| ZU01 |
|
Apr-01-1991 |
|
|
|
|
ZU |
ZU |
| ZW01 |
|
Nov-01-2005 |
|
|
|
|
ZW |
ZW |
Replacement & Obsolete Information
| Obsolete NIIN Information |
| Description: |
TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Originating Activity: |
XX |
| Hazardous Material: |
|
National Motor Freight Classification Number: |
063420 |
| Less Than One Truckload: |
W |
NMFC Sub-Item: |
Z |
| Uniform Freight Classification Number: |
35355 |
Rail Variance Code: |
|
| Less Than One Carload: |
|
Water Commodity Code: |
595 |
| Type of Cargo Code: |
Z |
Special Handling Code: |
9 |
| Air Commodity Special Handling Code: |
HZ |
Air Dimension Code: |
A |
| Source: |
P |
Primary Inventory Control Activity (PICA) |
Status: |
C |
| Pri/Sec ICC: |
P |
Container NSN: |
|
Category Code: |
69F0 |
| Lvl A Pkg Req: |
Q |
Unit Pack Size: |
|
Pres Material: |
00 |
| Lvl B Pkg Req: |
Q |
Unit Pack Weight: |
0.0 |
Pres Method: |
10 |
| Lvl C Pkg Req: |
U |
Unit Pack Cube: |
0.009 |
Wrapping Mat: |
DA |
| Opt Proc Ind: |
O |
Unpkg Item Dims: |
|
Spec Marking: |
00 |
| Container FSC: |
|
SPI Number: |
|
SPI Revision: |
|
| Unpkg Weight: |
|
SPI Date: |
|
Pkg Design Activity: |
14933
|
| Inter Container Qty: |
AAA |
Inter Container Code: |
D1 |
Clean/Dry Procedure: |
1 |
| Unit Container: |
A1 |
Item Type Storage: |
A |
Unit Container Level: |
|
| |
|
Cush/Dun Material: |
00 |
Cush/Dun Thickness: |
0 |
|