| MRC |
Requirement Statement |
Reply Statement |
| AAJD |
THREAD CLASS |
2B SINGLE GROUP |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND SINGLE GROUP |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ACYW |
IMPEDANCE RATING IN OHMS |
600.0 NOMINAL |
| ACYW |
IMPEDANCE RATING IN OHMS |
50.0 NOMINAL |
| ACYW |
IMPEDANCE RATING IN OHMS |
160.0 NOMINAL |
| ACZB |
FREQUENCY RATING |
300.0 HERTZ MINIMUM AND 3.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
| ACZF |
MAXIMUM TRANSFORMER POWER RATING |
3.0 WATTS SINGLE COMPONENT |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| ADAQ |
BODY LENGTH |
1.250 INCHES MINIMUM AND 1.312 INCHES MAXIMUM |
| ADAT |
BODY WIDTH |
1.250 INCHES MINIMUM AND 1.312 INCHES MAXIMUM |
| ADAU |
BODY HEIGHT |
1.625 INCHES MINIMUM AND 1.750 INCHES MAXIMUM |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
1.234 INCHES MINIMUM AND 1.266 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AFGR |
FREQUENCY RESPONSE TOLERANCE IN DECIBELS |
-0.5 TO 0.5 SINGLE COMPONENT |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AKPV |
MOUNTING FACILITY QUANTITY |
2 |
| AXGY |
MOUNTING METHOD |
THREADED HOLE(S) SINGLE GROUP |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
| CMLP |
THREAD QUANTITY PER INCH |
32 SINGLE GROUP |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SINGLE GROUP |
| CQLC |
WINDING TAP LOCATION |
CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
| CRBZ |
WINDING OPERATING CURRENT |
500.0 MILLIAMPERES DC MAXIMUM |
| THSD |
THREAD SERIES DESIGNATOR |
UNIFIED NATIONAL COARSE (UNC) SINGLE GROUP |
| TTQY |
TERMINAL TYPE AND QUANTITY |
7 WIRE HOOK |