| MRC |
Requirement Statement |
Reply Statement |
| AAJD |
THREAD CLASS |
2A |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
11.500 INCHES NOMINAL |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
7.250 INCHES NOMINAL |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE |
| ACZF |
MAXIMUM TRANSFORMER POWER RATING |
1.208 VOLT-AMPERE |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL |
| ADAQ |
BODY LENGTH |
14.120 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
9.750 INCHES NOMINAL |
| ADAU |
BODY HEIGHT |
8.500 INCHES NOMINAL |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 |
| AXGY |
MOUNTING METHOD |
THREADED STUD |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY AND 3 SECONDARY |
| CMLP |
THREAD QUANTITY PER INCH |
16 |
| CQJX |
NOMINAL THREAD SIZE |
0.375 INCHES |
| CQLC |
WINDING TAP LOCATION |
TAP W/O CENTER TAP |
| CRBZ |
WINDING OPERATING CURRENT |
10.0 AMPERES AC MAXIMUM |
| CRBZ |
WINDING OPERATING CURRENT |
8.5 AMPERES AC MAXIMUM |
| CRBZ |
WINDING OPERATING CURRENT |
10.5 AMPERES AC MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
17.30 AC VOLTS MINIMUM AND 18.70 AC VOLTS MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
30.80 AC VOLTS MINIMUM AND 33.20 AC VOLTS MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
110.40 AC VOLTS MINIMUM AND 119.60 AC VOLTS MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
390.00 AC VOLTS MINIMUM AND 500.00 AC VOLTS MAXIMUM |
| FEAT |
SPECIAL FEATURES |
INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| TTQY |
TERMINAL TYPE AND QUANTITY |
11 THREADED STUD |