| MRC |
Requirement Statement |
Reply Statement |
| ABHP |
OVERALL LENGTH |
1.718 INCHES MAXIMUM |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.406 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| ABKW |
OVERALL HEIGHT |
1.480 INCHES MAXIMUM |
| ABMK |
OVERALL WIDTH |
0.852 INCHES MAXIMUM |
| ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AKDX |
WINDING QUANTITY |
1 |
| APCN |
COIL QUANTITY |
1 |
| APNA |
WINDING DC RESISTANCE RATING |
500.0 OHMS NOMINAL SINGLE WINDING |
| APNP |
DUTY TYPE |
CONTINUOUS |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE(S) SINGLE MOUNTING FACILITY |
| CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR SINGLE MOUNTING FACILITY |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
26.0 MILLIAMPERES DC SINGLE WINDING |
| CRXH |
TIME DELAY |
0.018 SECONDS MAXIMUM FIXED OPERATE TIME |
| CRXH |
TIME DELAY |
0.005 SECONDS MAXIMUM FIXED RELEASE TIME |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
18.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
3.0 AMPERES AC AND 3.0 AMPERES DC RESISTIVE LOAD |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| TTQY |
TERMINAL TYPE AND QUANTITY |
20 PIN ALL FUNCTIONS |