National Stock Number(NSN): 5940-01-054-5466 (5940010545466, 010545466)
| NIIN: |
01-054-5466⛔ |
Item Name: |
TERMINAL BOARD |
INC: |
00404
|
| FSC: |
5940
|
Assignment Date: |
Jan-21-1978 |
CRIT: |
X |
IIG: |
00404 |
| ISC: |
3 |
Date Standardized: |
Feb-18-1989 |
HMIC: |
N |
DODIC: |
|
| NSC: |
5 |
Cancellation Date: |
Dec-05-2013 |
PMIC: |
U |
FIIG: |
A011B0 |
| ESD: |
|
Schedule B: |
8536.90.8085 |
DEMIL: |
A |
DEMIL INT: |
1 |
| TIIC: |
4 |
Originator: |
CX |
ADPEC: |
|
RPDMRC: |
6 |
| NIIN: |
00-949-3133 |
Item Name: |
TERMINAL BOARD |
| FSC: |
5940 |
Replacement Date: |
Dec-05-2013 |
|
INC: |
00404 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
410 JJ 12 FP NH |
26405
|
REGAL BELOIT AMERICA, INC |
H |
3 |
2 |
5 |
ZZ |
|
|
|
|
|
|
|
410-D-12-FNH |
26405
|
REGAL BELOIT AMERICA, INC |
H |
3 |
2 |
|
|
|
|
|
|
|
|
|
410-D-12-FNH |
83330
|
DIALIGHT CORPORATION |
H |
5 |
9 |
4 |
9Z |
|
B |
|
|
|
|
|
410-JJ-12-NH-FP |
26405
|
REGAL BELOIT AMERICA, INC |
H |
5 |
9 |
4 |
9Z |
|
B |
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DF |
S9G |
Y |
N |
0 |
|
1 |
|
$12.10 |
EA |
|
SF9---N |
|
H |
| DM |
S9G |
Y |
Z |
0 |
|
1 |
|
$12.10 |
EA |
|
1-G2--- |
|
H |
| DS |
S9G |
Y |
N |
0 |
|
1 |
|
$12.10 |
EA |
|
------- |
|
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DF |
F |
5940009493133 |
|
|
|
|
| DS |
F |
5940009493133 |
|
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| AAMA |
MOUNTING HOLE DIAMETER |
0.125 INCHES |
| AAPB |
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS |
1000.0 |
| AAQL |
BODY STYLE |
A1 BARRIER TYPE |
| ABCS |
TERMINAL ROW QUANTITY |
2 |
| ABCT |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS |
0.250 INCHES |
| ABCU |
DISTANCE BETWEEN TERMINAL ROW CENTERS |
0.250 INCHES |
| ABCX |
BOARD CONSTRUCTION |
SOLID CONSTRUCTION |
| ABDB |
TERMINAL FACILITY QUANTITY |
12 |
| ABDU |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
3.250 INCHES |
| ABDV |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
0.250 INCHES |
| ABDW |
DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE |
0.188 INCHES |
| ABDX |
DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY |
0.125 INCHES |
| ABGN |
BOARD OVERALL LENGTH |
3.500 INCHES |
| ABGP |
BOARD OVERALL WIDTH |
0.625 INCHES |
| ABGQ |
BOARD OVERALL HEIGHT |
0.312 INCHES |
| ABGR |
BOARD HEIGHT EXCLUDING TERMINALS |
0.312 INCHES |
| ABGS |
BASE THICKNESS |
0.093 INCHES |
| AMPS |
CURRENT RATING IN AMPS |
5.0 |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE(S) |
| CBBL |
FEATURES PROVIDED |
FUNGUS PROOFING AND MOISTURE PROOFING |
| CWLG |
TERMINAL PATTERN ARRANGEMENT |
MULTI-ROW |
| CWLN |
TERMINAL DESIGN |
LINKED NONFEEDTHRU |
| MATT |
MATERIAL |
GLASS AND PLASTIC ALKYD BOARD |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| YS01 |
|
Apr-01-1991 |
|
|
|
|
YS |
YS |
Replacement & Obsolete Information
| Replaced / Replacement NIIN Information |
| FSC |
NIIN |
ISC |
Originator |
NSC |
Std. Date |
Status |
|
5940
|
00-949-3133
|
1 |
CX |
0 |
Dec-28-1975 |
H |
|