National Stock Number(NSN): 5930-01-305-3555 (5930013053555, 013053555)
| NIIN: |
01-305-3555 |
Item Name: |
SWITCH,THERMOSTATIC |
INC: |
00451
|
| FSC: |
5930
|
Assignment Date: |
Aug-04-1989 |
CRIT: |
X |
IIG: |
00451 |
| ISC: |
5 |
Date Standardized: |
Aug-04-1989 |
HMIC: |
P |
DODIC: |
|
| NSC: |
8 |
Cancellation Date: |
Dec-14-2017 |
PMIC: |
A |
FIIG: |
A048B0 |
| ESD: |
|
Schedule B: |
9032.10.0000 |
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
M |
Originator: |
97 |
ADPEC: |
|
RPDMRC: |
6 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
1609-90 |
21447
|
EMERSON ELECTRICWHITE-ROGERS CONTROLS DIV |
H |
3 |
2 |
3 |
XF |
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| GP |
ZIC |
C |
C |
0 |
U |
1 |
C |
$26.88 |
EA |
|
S-09--- |
Oct-01-1992 |
H |
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ABTD |
MOUNTING SLOT WIDTH |
0.187 INCHES NOMINAL |
| AEVT |
CAPILLARY TUBE LENGTH |
96.0 INCHES NOMINAL |
| AEVU |
BULB LENGTH |
5.750 INCHES NOMINAL |
| AEVV |
BULB DIAMETER |
0.375 INCHES NOMINAL |
| AGAV |
END ITEM IDENTIFICATION |
CONTROLLER/STARTER USED ONBOARD 180 FT WLB COAST GUARD VESSELS |
| AKBY |
TEMP SENSING ELEMENT TYPE |
CAPILLARY TUBE-BULB |
| AXGY |
MOUNTING METHOD |
SLOT |
| CBME |
CUBIC MEASURE |
5.000 CUBIC INCHES |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, DOUBLE MAKE, BOTH POSITIONS MAINTAINED, WITH CONTACT ON ARM |
| CSCF |
TERMINAL TYPE |
SCREW |
| CTHF |
CONTACT LOAD CURRENT RATING |
7.4 AMPERES MOTOR LOAD FIRST VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
3.7 AMPERES MOTOR LOAD SECOND VOLTAGE |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT ADJUSTABLE, PRESET AND DEACTUATION POINT ADJUSTABLE, PRESET |
| CTYM |
CONTACT ADJUSTMENT RANGE |
50.00 TO 90.00 ACTUATION POINT DEGREES FAHRENHEIT AND -30.00 TO 10.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CTYS |
CONTACT ADJUSTMENT TYPE |
INTERNAL ACTUATION POINT POINTER WITH SCALE AND INTERNAL DEACTUATION POINT POINTER WITH SCALE |
| CTYX |
CONTACT STIMULUS RATING |
90.00 ACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND -30.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
120.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
240.0 AC AT SEA LEVEL SECOND VOLTAGE |
| FREQ |
FREQUENCY IN HERTZ |
60.0 FIRST VOLTAGE |
| FREQ |
FREQUENCY IN HERTZ |
60.0 SECOND VOLTAGE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS |
|