| MRC |
Requirement Statement |
Reply Statement |
| AAJD |
THREAD CLASS |
2B SINGLE MOUNTING FACILITY |
| ABHP |
OVERALL LENGTH |
4.710 INCHES MINIMUM AND 4.780 INCHES MAXIMUM |
| ABKW |
OVERALL HEIGHT |
3.660 INCHES MINIMUM AND 3.720 INCHES MAXIMUM |
| ABMK |
OVERALL WIDTH |
2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM |
| ABWV |
SHAFT DIAMETER |
0.249 INCHES MINIMUM AND 0.251 INCHES MAXIMUM SINGLE ACTUATOR |
| ABXF |
SHAFT LENGTH |
0.930 INCHES MINIMUM AND 0.940 INCHES MAXIMUM SINGLE ACTUATOR |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.164 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AFBH |
INDIVIDUAL SECTION QUANTITY |
3 |
| AFDS |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS |
1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AFGA |
OPERATING TEMP RANGE |
-55.0 TO 125.0 CELSIUS |
| AJZE |
SWITCH CONTACT BASIC DESIGN |
NONPILE-UP SYMMETRICAL |
| AKPX |
POLE QUANTITY |
2 EACH SECTION FRONT |
| AKPY |
THROW QUANTITY |
24 EACH SECTION FRONT |
| AXGY |
MOUNTING METHOD |
THREADED HOLE(S) SINGLE MOUNTING FACILITY |
| CMLP |
THREAD QUANTITY PER INCH |
32 SINGLE MOUNTING FACILITY |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES SINGLE MOUNTING FACILITY |
| CQMK |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE SINGLE MOUNTING FACILITY |
| CRJH |
SWITCH ACTUATOR INDEXING POSITION QUANTITY |
24 SINGLE ACTUATOR |
| CRSJ |
SHAFT TYPE |
ROUND SINGLE ACTUATOR |
| CSCF |
TERMINAL TYPE |
TURRET |
| CSHW |
CONTACT SWITCHING ACTION |
BREAKS BEFORE MAKES EACH SECTION FRONT |
| CSLC |
SWITCH ACTUATOR POSITIONING INCREMENT |
7.5 DEGREES SINGLE ACTUATOR |
| CTDN |
SWITCH ACTUATOR STOP DEVICE TYPE |
FIXED STOP SINGLE ACTUATOR |
| CTHF |
CONTACT LOAD CURRENT RATING |
2.0 MILLIAMPERES RESISTIVE LOAD DC AT SEA LEVEL |
| STYL |
STYLE DESIGNATOR |
11 TAP, SQUARE FRAME |
| THSD |
THREAD SERIES DESIGNATOR |
UNIFIED NATIONAL COARSE (UNC) SINGLE MOUNTING FACILITY |