| MRC |
Requirement Statement |
Reply Statement |
| ABHP |
OVERALL LENGTH |
1.312 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
0.344 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
0.750 INCHES NOMINAL |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
0.937 INCHES NOMINAL |
| AKBY |
TEMP SENSING ELEMENT TYPE |
INTERNAL SENSOR |
| AWTN |
OPERATING TEMP RATING |
-76.0 FAHRENHEIT MINIMUM AND 400.0 FAHRENHEIT MAXIMUM |
| AXGY |
MOUNTING METHOD |
BRACKET(S) |
| CBBL |
FEATURES PROVIDED |
HERMETICALLY SEALED CASE |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE |
| CSCF |
TERMINAL TYPE |
WIRE LEAD |
| CTHF |
CONTACT LOAD CURRENT RATING |
8.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
4.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
10.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
1.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT NOT ADJUSTABLE |
| CTYX |
CONTACT STIMULUS RATING |
104.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 82.40 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
125.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
250.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
30.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
125.0 DC AT SEA LEVEL FOURTH VOLTAGE |