| MRC |
Requirement Statement |
Reply Statement |
| AAQL |
BODY STYLE |
1B MULTIPOLE-SINGLE ACTUATOR TYPE |
| ABXD |
BUSHING LENGTH |
0.370 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
1.562 INCHES MAXIMUM |
| ADAT |
BODY WIDTH |
1.281 INCHES MAXIMUM |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.875 INCHES NOMINAL |
| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.625 INCHES NOMINAL |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.147 INCHES NOMINAL |
| AEFQ |
NONTURN DEVICE LENGTH |
0.075 INCHES MAXIMUM |
| AEFR |
NONTURN DEVICE WIDTH |
0.125 INCHES MAXIMUM |
| AGAV |
END ITEM IDENTIFICATION |
SSDS MK2,MOD |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
0.380 INCHES MAXIMUM |
| AKPX |
POLE QUANTITY |
2 |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED HOLE(S) |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
4.0 AMPERES AC AND 4.0 AMPERES DC ALL LOCATIONS |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
50.0 DC AND 240.0 AC ALL LOCATIONS |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
4.0 AC ALL LOCATIONS |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
400.0 ALL LOCATIONS |
| CPRP |
ULTIMATE TRIP TIME PER POLE IN SECONDS |
0.015 NOMINAL ALL LOCATIONS |
| CPRQ |
RESET METHOD |
MANUAL |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| CPRX |
ACTUATOR POSITION DESIGNATION |
BETWEEN POLE ONE AND TWO |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
| CQQC |
TRIP RELEASE DUTY CYCLE |
CONTINUOUS ALL LOCATIONS |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
3.0 MINIMUM AT 150 PCT AND 70.0 MAXIMUM AT 150 PCT AND 0.05 MINIMUM AT 200 PCT AND 20.0 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCK RESISTANT |
| CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
25.0 CELSIUS NOMINAL ALL LOCATIONS |
| CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
CIRCUIT BREAKER |
| FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
| MATT |
MATERIAL |
PLASTIC CASE |
| TEST |
TEST DATA DOCUMENT |
MIL-STD-202 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TTQY |
TERMINAL TYPE AND QUANTITY |
4 WIRE HOOK |
| ZZZK |
SPECIFICATION/STANDARD DATA |
MIL-PRF-39019 GOVERNMENT SPECIFICATION |