National Stock Number(NSN): 5925-01-373-1036 (5925013731036, 013731036)
| NIIN: |
01-373-1036 |
Item Name: |
CIRCUIT BREAKER |
INC: |
00136
|
| FSC: |
5925
|
Assignment Date: |
Mar-27-1993 |
CRIT: |
|
IIG: |
00136 |
| ISC: |
5 |
Date Standardized: |
Mar-27-1993 |
HMIC: |
P |
DODIC: |
|
| NSC: |
5 |
Cancellation Date: |
Oct-01-1997 |
PMIC: |
A |
FIIG: |
|
| ESD: |
|
Schedule B: |
|
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
|
Originator: |
97 |
ADPEC: |
|
RPDMRC: |
|
| NIIN: |
01-343-3592 |
Item Name: |
CIRCUIT BREAKER |
| FSC: |
5925 |
Replacement Date: |
Oct-01-1997 |
|
INC: |
00136 |
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
ED63A015 |
0SSZ8
|
SPORT MART WHOLESALAERS, INC. DBA SMW ASPHALT PLANT SERVICES CO. |
H |
5 |
2 |
5 |
TX |
|
|
|
|
|
|
|
ED63A015 |
66842
|
SIEMENS ENERGY AND AUTOMATION INC ITE CIRCUIT PROTECTION DIV |
H |
3 |
2 |
E |
TX |
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DN |
S9E |
Y |
|
0 |
U |
0 |
N |
$298.00 |
EA |
|
9N----- |
Oct-01-1997 |
H |
| DS |
S9E |
Y |
|
0 |
U |
0 |
D |
$298.00 |
EA |
|
------- |
Oct-01-1997 |
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DN |
Z |
DISCNT USE 5925-01-343-3592 |
000 |
|
|
|
| DS |
Z |
DISCNT USE 5925-01-343-3592 |
000 |
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| AAQL |
BODY STYLE |
1D RECTANGULAR DIMENSIONAL ENVELOPE |
| ABHP |
OVERALL LENGTH |
6.343 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
3.000 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
4.406 INCHES NOMINAL |
| ADTV |
CASE MATERIAL |
PLASTIC |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.164 INCHES NOMINAL |
| AKPX |
POLE QUANTITY |
3 |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE(S) |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
15.0 AMPERES AC ALL LOCATIONS |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
600.0 AC ALL LOCATIONS |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
18000.0 AC ALL LOCATIONS |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS ALL LOCATIONS |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 ALL LOCATIONS |
| CPRQ |
RESET METHOD |
MANUAL |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
| FREQ |
FREQUENCY IN HERTZ |
60.0 ALL LOCATIONS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 COMPRESSION |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| N9ND |
|
Mar-27-1993 |
3 |
Z |
Z |
HD |
HD |
|
|