National Stock Number(NSN): 5925-00-265-2271 (5925002652271, 002652271)
| NIIN: |
00-265-2271⛔ |
Item Name: |
CIRCUIT BREAKER |
INC: |
00136
|
| FSC: |
5925
|
Assignment Date: |
|
CRIT: |
|
IIG: |
00136 |
| ISC: |
3 |
Date Standardized: |
|
HMIC: |
|
DODIC: |
|
| NSC: |
8 |
Cancellation Date: |
Feb-08-2000 |
PMIC: |
U |
FIIG: |
A030A0 |
| ESD: |
|
Schedule B: |
|
DEMIL: |
B |
DEMIL INT: |
|
| TIIC: |
4 |
Originator: |
|
ADPEC: |
|
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
8734K1 |
15605
|
EATON CORP OPNS & TECHNICAL CENTER |
H |
5 |
9 |
|
|
|
|
|
|
|
|
|
8734K1 |
81640
|
SAFRAN POWER USA, LLC |
H |
3 |
2 |
|
|
|
|
|
|
|
|
|
C5809B |
81349
|
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M |
H |
2 |
2 |
|
|
|
|
|
|
|
|
|
E1441-25 |
10001
|
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER |
H |
3 |
2 |
|
|
|
|
|
|
|
|
|
E761100-11 |
38597
|
LOCKHEED MARTIN CORPORATION |
H |
5 |
2 |
|
|
|
|
|
|
|
|
|
MILC5809 |
81349
|
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M |
H |
4 |
1 |
|
|
|
|
|
|
|
|
| MOEC |
SOS |
A A C |
R C |
S L C |
CIIC |
U P Q |
U S C |
Unit Price |
UI |
UICF |
MCD |
Action Date |
C/H |
| DN |
S9E |
Y |
|
0 |
|
1 |
|
$2.22 |
EA |
|
9N----- |
|
H |
| MOEC |
PC |
Phrase |
QPA |
UOM |
OOU |
JTC |
| DN |
F |
5925007033589 |
|
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ADTV |
CASE MATERIAL |
METAL |
| AKPX |
POLE QUANTITY |
1 |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED HOLE |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
25.0 AMPERES DC |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
28.0 DC |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1500.0 DC |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT |
| CPRJ |
TRIP RELEASE METHOD |
THERMAL |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
138.0 |
| CPRQ |
RESET METHOD |
MANUAL |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
10.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
MOISTURE RESISTANT AND EXPLOSION RESISTANT |
| CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
25.0 DEG CELSIUS NOMINAL |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-C-5809 SPECIFICATION |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 SCREW |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| ZT01 |
|
|
|
|
|
|
ZT |
ZT |
Replacement & Obsolete Information
| Replaced / Replacement NIIN Information |
| Obsolete NIIN Information |
|