| MRC |
Requirement Statement |
Reply Statement |
| ABHP |
OVERALL LENGTH |
16.000 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
5.000 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
1.250 INCHES NOMINAL |
| ADAU |
BODY HEIGHT |
1.250 INCHES NOMINAL |
| AECR |
VIBRATION RESISTANCE RANGE IN HERTZ |
10.0 TO 55.0 |
| AFGA |
OPERATING TEMP RANGE |
-56.0 TO 70.0 CELSIUS |
| AHAJ |
REFERENCE FREQUENCY PER FUNCTION |
1307.5 MEGAHERTZ 1ST BAND PASS 1ST FUNCTION |
| AHAJ |
REFERENCE FREQUENCY PER FUNCTION |
1090.0 MEGAHERTZ 2ND BAND SUPPRESSION 2ND FUNCTION |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 BRACKET(S) SINGLE FUNCTION |
| CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
0.3 1ST BAND PASS 1ST FUNCTION |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS SINGLE BAND PASS 1ST FUNCTION |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS SINGLE BAND SUPPRESSION 2ND FUNCTION |
| CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
30.0 2ND BAND SUPPRESSION 2ND FUNCTION |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 CONNECTOR, RECEPTACLE OUTPUT AND 1 CONNECTOR, PLUG INPUT SINGLE FUNCTION |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS SINGLE BAND SUPPRESSION 2ND FUNCTION |
| AHBZ |
VOLTAGE STANDING WAVE RATIO PER FUNCTION |
1.3 SINGLE BAND PASS 1ST FUNCTION |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
1215.00 MEGAHERTZ 1ST BAND PASS AND 1400.00 MEGAHERTZ 1ST BAND PASS 1ST FUNCTION |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
1085.00 MEGAHERTZ 2ND BAND SUPPRESSION AND 1095.00 MEGAHERTZ 2ND BAND SUPPRESSION 2ND FUNCTION |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
30.0 2ND BAND SUPPRESSION SECOND FUNCTION |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 CONNECTOR, RECEPTACLE OUTPUT AND 1 CONNECTOR, PLUG INPUT SINGLE FUNCTION |
| CQRG |
BODY MATERIAL |
ALUMINUM |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
1215.00 MEGAHERTZ 1ST BAND PASS AND 1400.00 MEGAHERTZ 1ST BAND PASS FIRST FUNCTION |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
1085.00 MEGAHERTZ 2ND BAND SUPPRESSION AND 1095.00 MEGAHERTZ 2ND BAND SUPPRESSION SECOND FUNCTION |
| CTJS |
UNPACKAGED UNIT WEIGHT |
10.000 OUNCES NOMINAL |
| STYL |
STYLE DESIGNATOR |
27 RECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS SINGLE BAND PASS 1ST FUNCTION |
| AHBZ |
VOLTAGE STANDING WAVE RATIO PER FUNCTION |
1.3 SINGLE BAND SUPPRESSION 2ND FUNCTION |