National Stock Number(NSN): 5915-01-256-9575 (5915012569575, 012569575)

NIIN: 01-256-9575 Item Name: FILTER,RADIO FREQUENCY INTERFERENCE INC: 00765
FSC: 5915 Assignment Date: Jun-10-1987 CRIT: X IIG: 00765
ISC: 6 Date Standardized: Aug-23-1989 HMIC: P DODIC:
NSC: 0 Cancellation Date: PMIC: A FIIG: A047B0
ESD: Schedule B: 8527.99.5030 DEMIL: Q DEMIL INT: 3
TIIC: 1 Originator: TX ADPEC: RPDMRC:
Advantages & Benefits to a full LogiQuest subscription:

With a full subscription to LogiQuest, you can affordably maintain readiness of US military equipment, view current and historical NSN pricing, find substitutable manufacturer’s part numbers, analyze weapon systems, view detailed vendor data, proactively address DMSMS and bid on government selling opportunities. Directly search 60+ databases from Navy, Army, Air Force, Marines, and commercial sources. Examples include APL, AMDF, Milspecs, CAGE, SAM, EPLS, QPL, QPD, and many more.

The full version of LogiQuest has information related to NSN 5915-01-256-9575 in each of the following databases.

 • PROCUREMENT - Procurement History
 • PID - Procurement Item Description
 • SUPPTECH - Supplemental Technical Information
 • AWARDS - Awards Information
 • CRF - NICP Cross Reference File
 • ILS_INV - ILS Aviation Parts Availability
 • LIRSH - List of Items Requiring Special Handling
 • NMDF - Navy Master Data File
 • NNRF - Navy NIIN Reference File
 • PROJECTIONS - Projected Future Procurements
 • WHEREUSED - Where NIIN Used
 • WPS - Weapons Systems
 • WUC_HIST - Historical Work Unit Codes
 • CAGE - Commercial And Government Entity
 • H6 - Federal Item Name Directory
 • FSC - Federal Supply Class
 • Schedule B - Export Commodity Classifications

Contact us to request your free trial of LogiQuest® today.

Learn More

To learn more about LogiQuest® click here.

Please note that LogiQuest Lite is an informational service only.  Clicking on the CAGE codes below will provide contact information for possible sources of supply.


  Contact an advertising partner for price and availability for this item.
Part Information
Part Number CAGE Company Status RN CC RN VC DAC RN AAC RN FC RN SC RN JC SADC HCC MSDS
704AS2802-2 30003 NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER C 3 2 A TX
A3585 23939 THE CAPTOR CORPORATION C 5 2 6 TX
CSK10263 12294 MURATA ERIE NORTH AMERICA INC DIVOF MURATA ERIE C 5 9 6 TX B
FC2515 56528 FIL-COIL INTERNATIONAL LLC C 5 9 5 ZZ B
M1806 59901 MTK ELECTRONICS INC C 5 2 5 ZZ
RME-F-0088 0S2B1 RME FILTERS INC C 5 2 5 ZZ
TRN05-010059-01 0LSP2 SPECTRUM CONTROL, INC. C 5 2 5 ZZ
TRN05-010059-01 33095 SPECTRUM CONTROL INC C 5 9 5 TX B
Management Information
MOEC SOS A A C R C S L C CIIC U P Q U S C Unit Price UI UICF MCD Action Date C/H
DN SMS J 0 U 1 N $1,021.64 EA 9B----- Oct-01-2025 C
DS SMS J 0 U 1 D $1,120.59 EA ------- Oct-01-2022 H
DS SMS J 0 U 1 I $1,021.64 EA ------- Oct-01-2025 C
Technical Characteristics Information
MRC Requirement Statement Reply Statement
ABHP OVERALL LENGTH 3.825 INCHES MAXIMUM
ABKW OVERALL HEIGHT 3.000 INCHES MAXIMUM
ADAQ BODY LENGTH 3.080 INCHES MAXIMUM
ADAT BODY WIDTH 1.980 INCHES MAXIMUM
ADAU BODY HEIGHT 2.750 INCHES MAXIMUM
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.430 INCHES NOMINAL
AFGA OPERATING TEMP RANGE -65.0 TO 125.0 CELSIUS
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 4TH RADIO INTERFERENCE THIRD FUNCTION
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 1.0 1ST RADIO INTERFERENCE FIRST FUNCTION
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 1.0 2ND RADIO INTERFERENCE SECOND FUNCTION
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 1.0 3RD RADIO INTERFERENCE THIRD FUNCTION
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 2.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.2 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.2 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 1.2 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 2.8 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE FOURTH FUNCTION
AHBN INPUT TERMINAL MANUFACTURER CODE 96906
AHBP INPUT TERMINAL IDENTIFICATION MS27471Y11D98P
AHCG MAXIMUM TEMP RISE 25.0 CELSIUS
AKEJ MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNIFIED NATIONAL COARSE (UNC)
AKNA INCLOSURE TYPE ENCASED
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT FIRST FUNCTION
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 4 TAB, SOLDER LUG OUTPUT SECOND FUNCTION
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 TAB, SOLDER LUG GROUND THIRD FUNCTION
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 120.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 120.0 VOLTS AC 2ND RADIO INTERFERENCE SECOND FUNCTION
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 120.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 28.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
CQJX NOMINAL THREAD SIZE 0.138 INCHES
CQRG BODY MATERIAL METAL
CRDC MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE 700.0 VOLTS AT SEA LEVEL
STYL STYLE DESIGNATOR 27 RECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES
MOE Rules Information
MOE Rule Former MOER Effective AMC AMSC IMC IMCA Collaborators Receivers
N9BN N9ND Jun-01-2006 1 L Z KE GX|GT|KE GH|GX
Freight Information

Description: ELECTRICAL EQUIP:FILTERS Originating Activity: TX
Hazardous Material: National Motor Freight Classification Number: 061990
Less Than One Truckload: P NMFC Sub-Item: X
Uniform Freight Classification Number: 58500 Rail Variance Code:
Less Than One Carload: Water Commodity Code: 72D
Type of Cargo Code: Z Special Handling Code: 9
Air Commodity Special Handling Code: HZ Air Dimension Code: A
Integrity Code:
Packaging Information

Source: P Primary Inventory Control Activity (PICA) Status: C
Pri/Sec ICC: P Container NSN: Category Code: 69F0
Lvl A Pkg Req:  Q  Unit Pack Size: Pres Material: 00
Lvl B Pkg Req:  Q  Unit Pack Weight: 0.1 Pres Method: 42
Lvl C Pkg Req:    Unit Pack Cube: 0.028 Wrapping Mat: EA
Opt Proc Ind:  O  Unpkg Item Dims: Spec Marking: 00
Supp Inst: IP025: PACKAGING, MARKING, 
Container FSC: SPI Number: SPI Revision:   
Unpkg Weight: SPI Date: Pkg Design Activity: 14933
Inter Container Qty: AAA Inter Container Code: DO Clean/Dry Procedure: 1
Unit Container: ZZ Item Type Storage:  B  Unit Container Level:   
    Cush/Dun Material: DA Cush/Dun Thickness: C