| MRC |
Requirement Statement |
Reply Statement |
| AAFZ |
BODY MATERIAL |
STEEL |
| ABHP |
OVERALL LENGTH |
9.410 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
8.000 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
5.000 INCHES NOMINAL |
| ADAU |
BODY HEIGHT |
4.750 INCHES NOMINAL |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
4.000 INCHES NOMINAL |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
63.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
63.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
63.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
30.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
30.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
30.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| AJYN |
SCREW THREAD DIAMETER |
0.190 INCHES NOMINAL |
| AJYP |
SCREW THREAD SERIES DESIGNATOR |
UNF |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED STUD(S) 1ST FUNCTION |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 SLOT 2ND FUNCTION |
| CFHK |
SCREW THREAD QUANTITY PER INCH |
32 |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
3 THREADED STUD INPUT 1ST FUNCTION |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
3 THREADED STUD OUTPUT 2ND FUNCTION |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
4 THREADED STUD GROUND 3RD FUNCTION |
| CQFT |
FUNCTIONAL TERMINAL THREAD DIAMETER |
0.190 INCHES INPUT |
| CQFT |
FUNCTIONAL TERMINAL THREAD DIAMETER |
0.190 INCHES OUTPUT |
| CQFT |
FUNCTIONAL TERMINAL THREAD DIAMETER |
0.190 INCHES GROUND |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
460.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
460.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
460.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| CRBK |
FUNCTIONAL TERMINAL THREAD QUANTITY |
32.0 PER INCH INPUT |
| CRBK |
FUNCTIONAL TERMINAL THREAD QUANTITY |
32.0 PER INCH OUTPUT |
| CRBK |
FUNCTIONAL TERMINAL THREAD QUANTITY |
32.0 PER INCH GROUND |
| CRDB |
FUNCTIONAL TERMINAL THREAD SERIES DESIGNATOR |
INPUT UNF |
| CRDB |
FUNCTIONAL TERMINAL THREAD SERIES DESIGNATOR |
OUTPUT UNF |
| CRDB |
FUNCTIONAL TERMINAL THREAD SERIES DESIGNATOR |
GROUND UNF |
| CRDC |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE |
3.6 KILOVOLTS AT SEA LEVEL |
| FEAT |
SPECIAL FEATURES |
2.5 KILOVOLTS DC LINE TO LINE TEST VOLTAGE |
| STYL |
STYLE DESIGNATOR |
5 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |