National Stock Number(NSN): 5915-01-158-1090 (5915011581090, 011581090)

NIIN: 01-158-1090 Item Name: FILTER,RADIO FREQUENCY INTERFERENCE INC: 00765
FSC: 5915 Assignment Date: Jul-18-1983 CRIT: X IIG: 00765
ISC: 6 Date Standardized: Feb-27-1993 HMIC: P DODIC:
NSC: 0 Cancellation Date: PMIC: S FIIG: A047B0
ESD: Schedule B: 8527.99.5030 DEMIL: D DEMIL INT: 1
TIIC: 1 Originator: TX ADPEC: RPDMRC:
Advantages & Benefits to a full LogiQuest subscription:

With a full subscription to LogiQuest, you can affordably maintain readiness of US military equipment, view current and historical NSN pricing, find substitutable manufacturer’s part numbers, analyze weapon systems, view detailed vendor data, proactively address DMSMS and bid on government selling opportunities. Directly search 60+ databases from Navy, Army, Air Force, Marines, and commercial sources. Examples include APL, AMDF, Milspecs, CAGE, SAM, EPLS, QPL, QPD, and many more.

The full version of LogiQuest has information related to NSN 5915-01-158-1090 in each of the following databases.

 • PROCUREMENT - Procurement History
 • PID - Procurement Item Description
 • SUPPTECH - Supplemental Technical Information
 • APL - Allowance Parts List
 • CHAIN - Consolidated History Alt. Item Numbers
 • CRF - NICP Cross Reference File
 • ILS_INV - ILS Aviation Parts Availability
 • LIRSH - List of Items Requiring Special Handling
 • NICN - Navy Item Control Number to NIIN
 • NMDF - Navy Master Data File
 • NNRF - Navy NIIN Reference File
 • WHEREUSED - Where NIIN Used
 • WPS - Weapons Systems
 • GDAPL 2010 - GD Allowance Parts List
 • CAGE - Commercial And Government Entity
 • H6 - Federal Item Name Directory
 • FSC - Federal Supply Class
 • Schedule B - Export Commodity Classifications

Contact us to request your free trial of LogiQuest® today.

Learn More

To learn more about LogiQuest® click here.

Please note that LogiQuest Lite is an informational service only.  Clicking on the CAGE codes below will provide contact information for possible sources of supply.


  Contact an advertising partner for price and availability for this item.
Part Information
Part Number CAGE Company Status RN CC RN VC DAC RN AAC RN FC RN SC RN JC SADC HCC MSDS
452-40024-61PW(100) 03554 AMPHENOL CANADA CORP C 5 2 5 TX
5189010-010 08718 ITT CANNON ELECTRIC PHOENIX DIV C 5 9 5 TX B
5189010-010 53711 NAVAL SEA SYSTEMS COMMAND C 3 2 A TX
5189010-010 62577 ANK TECHNOLOGY, INC C 5 2 5 TX
5915PL0986676 9009H JEDNOLITY INDEKS MATERIALOWY - UNIFORM MATERIAL INDEX C 6 9 9 WP 4 B
81019-24-61PW 11139 TE CONNECTIVITY CORPORATION C 5 2 E TX
Additional Part Information
Part Number CAGE Company Source RN CC RN VC DAC RN AAC RN FC RN SC RN JC SADC HCC MSDS
452-40024-61PW{100} 03554 AMPHENOL CANADA CORP CRF 5 2 5 TX N 0
5189010-010 03554 AMPHENOL CANADA CORP CRF,APL 5 2 5 HD N 0
5189010-010 0JXN5 TRANSLANT INC A JOINT VENTURE CRF 3 2 5 HD N 0
5189010-010 11139 TE CONNECTIVITY CORPORATION CRF,APL 5 2 5 HD N 0
5189010-010 15090 RAYTHEON COMPANY CRF,APL 3 2 5 HD N 0
5189010-010 67346 GENERAL DYNAMICS VALLEY SYSTEMS DIV CRF 3 2 5 HD N 0
5189010-010 99584 HUGHES MISSILE SYSTEMS CO - POMONA CRF,APL 3 2 HD N 0
Management Information
MOEC SOS A A C R C S L C CIIC U P Q U S C Unit Price UI UICF MCD Action Date C/H
DN SMS J 0 7 1 N $247.09 EA 9B----- Oct-01-2025 C
DS SMS J 0 7 1 D $271.02 EA ------- Oct-01-2022 H
DS SMS J 0 7 1 I $247.09 EA ------- Oct-01-2025 C
Phrase Information
MOEC PC Phrase QPA UOM OOU JTC
DS X FORMERLY FSC 5935 000
Technical Characteristics Information
MRC Requirement Statement Reply Statement
ABHP OVERALL LENGTH 2.264 INCHES NOMINAL
ABKW OVERALL HEIGHT 1.796 INCHES MINIMUM AND 1.828 INCHES MAXIMUM
ABMK OVERALL WIDTH 1.796 INCHES MINIMUM AND 1.828 INCHES MAXIMUM
AECR VIBRATION RESISTANCE RANGE IN HERTZ 10.0 TO 500.0
AFGA OPERATING TEMP RANGE -55.0 TO 125.0 CELSIUS
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
AHAQ SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION
AHAS LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 1ST RADIO INTERFERENCE FIRST FUNCTION
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 2ND RADIO INTERFERENCE SECOND FUNCTION
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 3RD RADIO INTERFERENCE THIRD FUNCTION
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 5TH RADIO INTERFERENCE FIFTH FUNCTION
AHBB POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 6TH RADIO INTERFERENCE SIXTH FUNCTION
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.0 1ST RADIO INTERFERENCE FIRST FUNCTION
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.0 2ND RADIO INTERFERENCE SECOND FUNCTION
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.0 3RD RADIO INTERFERENCE THIRD FUNCTION
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.0 4TH RADIO INTERFERENCE FOURTH FUNCTION
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.0 5TH RADIO INTERFERENCE FIFTH FUNCTION
AHBC OPERATING CURRENT RATING PER FUNCTION IN AMPS 5.0 6TH RADIO INTERFERENCE SIXTH FUNCTION
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 2.5 VOLTS AC 1ST RADIO INTERFERENCE AND 8.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 2.5 VOLTS AC 2ND RADIO INTERFERENCE AND 8.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 2.5 VOLTS AC 3RD RADIO INTERFERENCE AND 8.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 2.5 VOLTS AC 4TH RADIO INTERFERENCE AND 8.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 2.5 VOLTS AC 5TH RADIO INTERFERENCE AND 8.0 VOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION
AHBE MAXIMUM VOLTAGE DROP PER FUNCTION 2.5 VOLTS AC 6TH RADIO INTERFERENCE AND 8.0 VOLTS DC 6TH RADIO INTERFERENCE SIXTH FUNCTION
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE FIRST FUNCTION
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE SECOND FUNCTION
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE THIRD FUNCTION
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE FOURTH FUNCTION
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE FIFTH FUNCTION
AHBL PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE SIXTH FUNCTION
AHBN INPUT TERMINAL MANUFACTURER CODE 11139
AHBP INPUT TERMINAL IDENTIFICATION MIL-C-26482
AHBS OUTPUT TERMINAL MANUFACTURER CODE 11139
AHBT OUTPUT TERMINAL IDENTIFICATION MIL-C-26482
AHCG MAXIMUM TEMP RISE 25.0 CELSIUS
AKEJ MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNEF
AKNA INCLOSURE TYPE HERMETICALLY SEALED
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING LOCATION NOT OTHERWISE SPECIFIED
CBBL FEATURES PROVIDED MOISTURE RESISTANT AND SHOCK RESISTANT
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 61 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT LOCATION NOT OTHERWISE SPECIFIED
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 250.0 VOLTS AC 1ST RADIO INTERFERENCE AND 800.0 VOLTS DC 1ST RADIO INTERFERENCE FIRST FUNCTION
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 250.0 VOLTS AC 2ND RADIO INTERFERENCE AND 800.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 250.0 VOLTS AC 3RD RADIO INTERFERENCE AND 800.0 VOLTS DC 3RD RADIO INTERFERENCE THIRD FUNCTION
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 250.0 VOLTS AC 4TH RADIO INTERFERENCE AND 800.0 VOLTS DC 4TH RADIO INTERFERENCE FOURTH FUNCTION
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 250.0 VOLTS AC 5TH RADIO INTERFERENCE AND 800.0 VOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION
CQGC OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 250.0 VOLTS AC 6TH RADIO INTERFERENCE AND 800.0 VOLTS DC 6TH RADIO INTERFERENCE SIXTH FUNCTION
CQJX NOMINAL THREAD SIZE 1.625 INCHES
CQRG BODY MATERIAL ALUMINUM
CRDC MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE 1.5 KILOVOLTS AT SEA LEVEL
CRST BODY SURFACE TREATMENT CADMIUM
FEAT SPECIAL FEATURES SIXTY-ONE FILTERED FUNCTIONS
PMLC PRECIOUS MATERIAL AND LOCATION CONTACT SURFACES SILVER
PRMT PRECIOUS MATERIAL SILVER
STYL STYLE DESIGNATOR 46 FILTER CONNECTOR
MOE Rules Information
MOE Rule Former MOER Effective AMC AMSC IMC IMCA Collaborators Receivers
N9BN N9ND Jun-01-2006 1 G Z HD GX|GT|HD GH|GX
YA01 Dec-01-2001 YA YA
YB01 May-01-1997 YB YB
YD01 Nov-01-2016 YD YD
YW01 Jun-01-1996 YW YW
ZC01 Apr-01-1991 ZC ZC
ZG01 Apr-01-1991 ZG ZG
ZJ01 Apr-01-2025 ZJ ZJ
ZP01 Sep-01-2006 ZP ZP
WG01 Nov-01-2017 WG WG
WP01 Mar-01-2004 WP WP
ZU01 Jul-01-2005 ZU ZU
ZW01 Nov-01-1998 ZW ZW
Replacement & Obsolete Information
NICN Information
FSC NICN Status
LL-HDN-F332 H
LL-TJ2-2458 H
Freight Information

Description: ELECTRICAL EQUIP:FILTERS Originating Activity: TX
Hazardous Material: National Motor Freight Classification Number: 061990
Less Than One Truckload: P NMFC Sub-Item: X
Uniform Freight Classification Number: 58500 Rail Variance Code:
Less Than One Carload: Water Commodity Code: 72D
Type of Cargo Code: Z Special Handling Code: 9
Air Commodity Special Handling Code: HZ Air Dimension Code: A
Integrity Code:
Packaging Information

Source: P Primary Inventory Control Activity (PICA) Status: C
Pri/Sec ICC: P Container NSN: Category Code: 60F0
Lvl A Pkg Req:  Q  Unit Pack Size: Pres Material: 00
Lvl B Pkg Req:  Q  Unit Pack Weight: 0.3 Pres Method: 10
Lvl C Pkg Req:    Unit Pack Cube: 0.052 Wrapping Mat: 00
Opt Proc Ind:  O  Unpkg Item Dims: Spec Marking: 00
Supp Inst:  
Container FSC: SPI Number: SPI Revision:   
Unpkg Weight: SPI Date: Pkg Design Activity: 14933
Inter Container Qty: AAA Inter Container Code: D3 Clean/Dry Procedure: 1
Unit Container: A1 Item Type Storage:  B  Unit Container Level:   
    Cush/Dun Material: NA Cush/Dun Thickness: C