| MRC |
Requirement Statement |
Reply Statement |
| ABHP |
OVERALL LENGTH |
7.250 INCHES MAXIMUM |
| ABKW |
OVERALL HEIGHT |
3.125 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
6.000 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
9.000 INCHES NOMINAL |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.203 INCHES NOMINAL |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
6.630 INCHES NOMINAL |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
7.000 INCHES NOMINAL |
| AFGA |
OPERATING TEMP RANGE |
M55.0/P65.0 DEG CELSIUS |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
62.0 1ST RADIO INTERFERENCE |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
62.0 2ND RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
5.0 1ST RADIO INTERFERENCE |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
5.0 2ND RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
2.0 VOLTS AC 1ST RADIO INTERFERENCE |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
2.0 VOLTS AC 2ND RADIO INTERFERENCE |
| AHCG |
MAXIMUM TEMP RISE |
20.0 DEG CELSIUS |
| AHCJ |
FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ |
0.01 AND B0.1 AND B10000.0 |
| AHCK |
FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS |
60.0 AND B100.0 AND B100.0 |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 UNTHREADED HOLE |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
2 THREADED STUD INPUT |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
2 THREADED STUD OUTPUT |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
2 THREADED STUD GROUND |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
120.0 VOLTS AC 1ST RADIO INTERFERENCE AND 400.0 VOLTS DC 1ST RADIO INTERFERENCE |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
120.0 VOLTS AC 2ND RADIO INTERFERENCE AND 400.0 VOLTS DC 2ND RADIO INTERFERENCE |
| CQRG |
BODY MATERIAL |
METAL |
| CRST |
BODY SURFACE TREATMENT |
TIN |
| PKWT |
UNPACKAGED UNIT WEIGHT |
6.000 POUNDS |