| MRC |
Requirement Statement |
Reply Statement |
| ABHP |
OVERALL LENGTH |
5.500 INCHES MINIMUM AND 5.624 INCHES MAXIMUM |
| ADAR |
BODY OUTSIDE DIAMETER |
0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
| AECR |
VIBRATION RESISTANCE RANGE IN HERTZ |
5.0 TO 33.0 |
| AFGA |
OPERATING TEMP RANGE |
0.0 TO 60.0 CELSIUS |
| AFSV |
AVERAGE LIFE RATING IN HOURS |
10000.0 |
| AHAJ |
REFERENCE FREQUENCY PER FUNCTION |
3.0 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| AHAU |
INPUT IMPEDANCE PER FUNCTION W/LOAD |
50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| AHAV |
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT |
50.0 OHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| AHBN |
INPUT TERMINAL MANUFACTURER CODE |
80058 |
| AHBP |
INPUT TERMINAL IDENTIFICATION |
UG20C/U |
| AHBS |
OUTPUT TERMINAL MANUFACTURER CODE |
80058 |
| AHBT |
OUTPUT TERMINAL IDENTIFICATION |
UG1185U |
| AHBZ |
VOLTAGE STANDING WAVE RATIO PER FUNCTION |
1.5 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
1.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 CONNECTOR, PLUG INPUT FIRST FUNCTION |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 CONNECTOR, PLUG OUTPUT SECOND FUNCTION |
| CQFC |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION |
200.00 MEGAHERTZ BLANK AND 2.50 GIGAHERTZ BLANK AND 2.90 GIGAHERTZ BLANK AND 3.10 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
2.90 GIGAHERTZ BLANK AND 3.10 GIGAHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| CRBC |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS |
25.0 MINIMUM BLANK AND 1.0 MAXIMUM BLANK FIRST FUNCTION |
| STYL |
STYLE DESIGNATOR |
26 ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |