| MRC |
Requirement Statement |
Reply Statement |
| ABKW |
OVERALL HEIGHT |
2.625 INCHES NOMINAL |
| ADAQ |
BODY LENGTH |
1.562 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
1.375 INCHES NOMINAL |
| ADAU |
BODY HEIGHT |
2.250 INCHES NOMINAL |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
1.000 INCHES NOMINAL |
| AECR |
VIBRATION RESISTANCE RANGE IN HERTZ |
10.0 TO 55.0 |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
0.875 INCHES NOMINAL |
| AFGA |
OPERATING TEMP RANGE |
-40.0 TO 160.0 FAHRENHEIT |
| AHAJ |
REFERENCE FREQUENCY PER FUNCTION |
1.6 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| AHAU |
INPUT IMPEDANCE PER FUNCTION W/LOAD |
20.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| AHAV |
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT |
20.0 KILOHMS BLANK LOCATION NOT OTHERWISE SPECIFIED |
| AHBL |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE BLANK LOCATION NOT OTHERWISE SPECIFIED |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNIFIED NATIONAL COARSE (UNC) |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED |
| CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
6.0 BLANK LOCATION NOT OTHERWISE SPECIFIED |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 TAB, SOLDER LUG INPUT FIRST FUNCTION |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
2 TAB, SOLDER LUG GROUND THIRD FUNCTION |
| CQDZ |
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE |
500.0 VOLTS AT SEA LEVEL |
| CQFC |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION |
800.00 HERTZ BLANK AND 1.57 KILOHERTZ BLANK AND 1.63 KILOHERTZ BLANK AND 3.20 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
| CQRG |
BODY MATERIAL |
METAL |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
1.57 KILOHERTZ BLANK AND 1.63 KILOHERTZ BLANK LOCATION NOT OTHERWISE SPECIFIED |
| CRBC |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS |
40.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK FIRST FUNCTION |
| FEAT |
SPECIAL FEATURES |
USE 3 POUNDS FORCE IN TERMINAL STRENGTH TEST |
| STYL |
STYLE DESIGNATOR |
2 RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |