| MRC |
Requirement Statement |
Reply Statement |
| ABHP |
OVERALL LENGTH |
7.480 INCHES MINIMUM AND 7.520 INCHES MAXIMUM |
| ABKW |
OVERALL HEIGHT |
4.310 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
3.540 INCHES MINIMUM AND 3.580 INCHES MAXIMUM |
| ADAQ |
BODY LENGTH |
6.360 INCHES MINIMUM AND 6.400 INCHES MAXIMUM |
| ADAT |
BODY WIDTH |
2.420 INCHES MINIMUM AND 2.460 INCHES MAXIMUM |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.196 INCHES NOMINAL |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
7.115 INCHES MINIMUM AND 7.135 INCHES MAXIMUM |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
3.187 INCHES NOMINAL |
| AFGA |
OPERATING TEMP RANGE |
-55.0 TO 85.0 CELSIUS |
| AFSV |
AVERAGE LIFE RATING IN HOURS |
1000.0 |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
1000.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
1000.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
1000.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
10.0 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
2.0 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
12.0 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
12.0 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
0.5 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
0.5 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
100.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
100.0 MILLIVOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
100.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
100.0 MILLIVOLTS AC 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
100.0 MILLIVOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
100.0 MILLIVOLTS DC 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| AHBN |
INPUT TERMINAL MANUFACTURER CODE |
96906 |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
20 UNTHREADED HOLE(S) LOCATION NOT OTHERWISE SPECIFIED |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
2 CONNECTOR, RECEPTACLE INPUT AND 1 CONNECTOR, PLUG INPUT FIRST FUNCTION |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
11 THREADED STUD OUTPUT SECOND FUNCTION |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 1ST RADIO INTERFERENCE FIRST FUNCTION |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
28.0 VOLTS DC 2ND RADIO INTERFERENCE SECOND FUNCTION |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 3RD RADIO INTERFERENCE THIRD FUNCTION |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
115.0 VOLTS AC 4TH RADIO INTERFERENCE FOURTH FUNCTION |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
28.0 VOLTS DC 5TH RADIO INTERFERENCE FIFTH FUNCTION |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
28.0 VOLTS DC 6TH RADIO INTERFERENCE SIXTH FUNCTION |
| CQRG |
BODY MATERIAL |
METAL |
| FEAT |
SPECIAL FEATURES |
11 FUNCTIONS |
| STYL |
STYLE DESIGNATOR |
15 RECTANGULAR TERMINAL/TERMINALS ON ADJACENT SURFACES |
| TEST |
TEST DATA DOCUMENT |
97151-68D40003 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |