National Stock Number(NSN): 5915-00-436-0856 (5915004360856, 004360856)
| NIIN: |
00-436-0856 |
Item Name: |
FILTER,BAND PASS |
INC: |
00209
|
| FSC: |
5915
|
Assignment Date: |
|
CRIT: |
|
IIG: |
00209 |
| ISC: |
2 |
Date Standardized: |
|
HMIC: |
|
DODIC: |
|
| NSC: |
8 |
Cancellation Date: |
May-30-1997 |
PMIC: |
|
FIIG: |
A047B0 |
| ESD: |
|
Schedule B: |
|
DEMIL: |
B |
DEMIL INT: |
|
| TIIC: |
1 |
Originator: |
|
ADPEC: |
|
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
422-905 |
16424
|
ADVANCED MEASUREMENT INSTRUMENTS INC |
H |
3 |
2 |
|
|
|
|
|
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| ABKW |
OVERALL HEIGHT |
4.750 INCHES MAXIMUM |
| ADAQ |
BODY LENGTH |
2.500 INCHES MINIMUM |
| ADAT |
BODY WIDTH |
2.500 INCHES MINIMUM |
| ADAU |
BODY HEIGHT |
4.375 INCHES MINIMUM |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
1.969 INCHES MINIMUM |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.969 INCHES MINIMUM |
| AHAJ |
REFERENCE FREQUENCY PER FUNCTION |
13.25 KILOHERTZ BLANK |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
62.0 KILOHMS BLANK |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
62.0 KILOHMS BLANK |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNC |
| AKNA |
INCLOSURE TYPE |
ENCASED |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED STUD |
| CQDR |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS |
7.0 BLANK |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 TAB,SOLDER LUG INPUT |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 TAB,SOLDER LUG OUTPUT |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
2 TAB,SOLDER LUG GROUND |
| CQFC |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION |
12.75 KILOHERTZ BLANK AND 13.075 KILOHERTZ BLANK AND 13.425 KILOHERTZ BLANK AND 13.750 KILOHERTZ BLANK |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
| CRBB |
FREQUENCY BAND WIDTH PER FUNCTION |
12.75 KILOHERTZ BLANK AND 13.75 KILOHERTZ BLANK |
| CRBC |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS |
55.0 NOMINAL BLANK AND 8.5 NOMINAL BLANK AND 8.5 NOMINAL BLANK AND 55.0 NOMINAL BLANK |
|