National Stock Number(NSN): 5910-00-617-3531 (5910006173531, 006173531)
| NIIN: |
00-617-3531⛔ |
Item Name: |
CAPACITOR,FIXED,GLASS DIELECTRIC |
INC: |
00004
|
| FSC: |
5910
|
Assignment Date: |
Jan-01-1963 |
CRIT: |
X |
IIG: |
00004 |
| ISC: |
3 |
Date Standardized: |
Sep-11-1971 |
HMIC: |
P |
DODIC: |
|
| NSC: |
0 |
Cancellation Date: |
|
PMIC: |
U |
FIIG: |
A010B0 |
| ESD: |
|
Schedule B: |
8532.29.0040 |
DEMIL: |
A |
DEMIL INT: |
|
| TIIC: |
1 |
Originator: |
TX |
ADPEC: |
|
RPDMRC: |
|
| Part Number |
CAGE |
Company |
Status |
RN CC |
RN VC |
DAC |
RN AAC |
RN FC |
RN SC |
RN JC |
SADC |
HCC |
MSDS |
|
4112280-034 |
05869
|
RAYTHEON COMPANY |
C |
5 |
1 |
5 |
KE |
3 |
D |
|
|
|
|
|
4112280-34 |
05869
|
RAYTHEON COMPANY |
C |
5 |
1 |
5 |
KE |
3 |
D |
|
|
|
|
|
418211-124 |
96214
|
RAYTHEON COMPANY |
C |
5 |
1 |
6 |
48 |
3 |
D |
|
|
|
|
|
626002H221 |
28528
|
ITT INDUSTRIES INC ITT AEROSPACE COMMUNICATIONS DIV EAST |
C |
5 |
9 |
4 |
ZB |
1 |
B |
|
|
|
|
|
947995-1221 |
06481
|
NORTHROP GRUMMAN SYSTEMS CORPORATION |
C |
C |
1 |
5 |
ZZ |
3 |
D |
|
9F |
|
|
|
947995-1221 |
13973
|
LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISION |
C |
5 |
9 |
5 |
KE |
3 |
B |
|
|
|
|
|
99007997 |
D2416
|
THALES DEFENCE DEUTSCHLAND GMBH |
C |
5 |
2 |
9 |
ZG |
4 |
D |
|
|
|
|
|
99007997 |
F8224
|
THALES LAS FRANCE SAS |
C |
5 |
2 |
4 |
ZB |
|
D |
|
|
|
|
|
CY10-300V220UJ |
F0114
|
UNION TECHNIQUE ELECTRICITE |
C |
5 |
2 |
4 |
ZB |
3 |
D |
|
|
|
|
|
CY10C221J |
81349
|
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M |
C |
2 |
2 |
3 |
KE |
3 |
D |
4 |
|
|
|
|
CYFM10-300V220UJ |
F1621
|
VISHAY SA |
C |
5 |
2 |
4 |
ZB |
|
D |
|
|
|
|
|
MS35371-18 |
96906
|
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M |
C |
5 |
1 |
5 |
KE |
3 |
D |
|
|
|
|
|
MTLC11272-1 |
81349
|
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M |
C |
4 |
1 |
3 |
KE |
3 |
D |
|
|
|
|
|
99007997 |
F2427
|
THALES AIR DEFENCE |
H |
5 |
2 |
4 |
ZB |
3 |
D |
|
|
|
|
|
CYFM10-300V220UJ |
F2663
|
SFERNICE DIVISION SOVCOR |
H |
5 |
9 |
4 |
ZB |
3 |
D |
|
|
|
|
Technical Characteristics Information
| MRC |
Requirement Statement |
Reply Statement |
| AAQL |
BODY STYLE |
21A W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABJT |
TERMINAL LENGTH |
1.125 INCHES MINIMUM |
| ADAQ |
BODY LENGTH |
0.344 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
0.078 INCHES NOMINAL |
| ADAU |
BODY HEIGHT |
0.172 INCHES NOMINAL |
| AEBZ |
SCHEMATIC DIAGRAM DESIGNATOR |
1C NO COMMON OR GROUNDED ELECTRODE(S) |
| CQBQ |
CAPACITANCE VALUE PER SECTION |
220.000 PICOFARADS SINGLE SECTION |
| CQJJ |
NONDERATED OPERATING TEMP |
-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM |
| CQLZ |
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS |
140.0 SINGLE SECTION |
| CQWM |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION |
300.0 DC SINGLE SECTION |
| CRHD |
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS |
-25.0 TO 25.0 SINGLE SECTION |
| CRTP |
TOLERANCE RANGE PER SECTION |
-5.00 TO 5.00 PERCENT SINGLE SECTION |
| CWPK |
INSULATION RESISTANCE AT REFERENCE TEMP |
100000.0 MEGOHMS |
| CWPM |
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT |
0.0010 |
| CWQF |
QUALITY FACTOR AT REFERENCE TEMP |
1400.0000 |
| CWSG |
TERMINAL SURFACE TREATMENT |
SOLDER |
| MATT |
MATERIAL |
GLASS CASE |
| TEST |
TEST DATA DOCUMENT |
81349-MILC11272 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). AND 81349-MILC1127211 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 UNINSULATED WIRE LEAD |
| MOE Rule |
Former MOER |
Effective |
AMC |
AMSC |
IMC |
IMCA |
Collaborators |
Receivers |
| YA01 |
|
Feb-01-2001 |
|
|
|
|
YA |
YA |
| YB01 |
|
Apr-01-1991 |
|
|
|
|
YB |
YB |
| YD01 |
|
Aug-01-2016 |
|
|
|
|
YD |
YD |
| YW01 |
|
Jan-01-1998 |
|
|
|
|
YW |
YW |
| ZC01 |
|
Apr-01-1991 |
|
|
|
|
ZC |
ZC |
| ZF01 |
|
Apr-01-1991 |
|
|
|
|
ZF |
ZF |
| ZG01 |
|
Apr-01-1991 |
|
|
|
|
ZG |
ZG |
| ZK01 |
|
Apr-01-1991 |
|
|
|
|
ZK |
ZK |
| ZN01 |
|
Apr-01-1991 |
|
|
|
|
ZN |
ZN |
| ZR01 |
|
Apr-01-1991 |
|
|
|
|
ZR |
ZR |
| WG01 |
|
Oct-01-2017 |
|
|
|
|
WG |
WG |
| ZU01 |
|
Apr-01-1991 |
|
|
|
|
ZU |
ZU |
| ZW01 |
|
Apr-01-1991 |
|
|
|
|
ZW |
ZW |
Replacement & Obsolete Information
| Replaced / Replacement NIIN Information |
| FSC |
NIIN |
ISC |
Originator |
NSC |
Std. Date |
Status |
|
5910
|
00-426-7402
|
1 |
TX |
0 |
Jul-06-1978 |
C |
| Obsolete NIIN Information |
| Description: |
CONDENSERS/PARTS NOI/CAPACITORS |
Originating Activity: |
XX |
| Hazardous Material: |
|
National Motor Freight Classification Number: |
061400 |
| Less Than One Truckload: |
P |
NMFC Sub-Item: |
X |
| Uniform Freight Classification Number: |
34450 |
Rail Variance Code: |
|
| Less Than One Carload: |
P |
Water Commodity Code: |
658 |
| Type of Cargo Code: |
Z |
Special Handling Code: |
9 |
| Air Commodity Special Handling Code: |
HZ |
Air Dimension Code: |
A |
|