| MRC |
Requirement Statement |
Reply Statement |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABJT |
TERMINAL LENGTH |
1.370 INCHES MINIMUM |
| ADAQ |
BODY LENGTH |
0.300 INCHES MAXIMUM |
| ADAR |
BODY OUTSIDE DIAMETER |
0.105 INCHES MAXIMUM |
| AEBT |
TERMINAL DIAMETER |
0.020 INCHES NOMINAL |
| AEHX |
MAXIMUM POWER DISSIPATION RATING |
0.125 WATTS |
| AEHY |
AMBIENT TEMP AT FULL RATED POWER |
25.0 CELSIUS |
| AEHZ |
MAXIMUM OPERATING TEMP |
125.0 CELSIUS |
| AEJA |
THERMAL TIME CONSTANT IN SECONDS |
20.0 |
| AEJB |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS |
30.0 |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-55.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
-15.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
0.0 CELSIUS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
50.0 CELSIUS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
75.0 CELSIUS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
100.0 CELSIUS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER |
125.0 CELSIUS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
18.759 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
27.768 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
31.746 KILOHMS THIRD RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
47.190 KILOHMS FOURTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
55.77 KILOHMS FIFTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
65.13 KILOHMS SIXTH RESISTANCE-TEMPERATURE POINT |
| AEJE |
ZERO POWER RESISTANCE AT SPECIFIED TEMP |
74.1 KILOHMS SEVENTH RESISTANCE-TEMPERATURE POINT |
| AEJF |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT |
-10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS |
| AGAV |
END ITEM IDENTIFICATION |
SINCGARS-V |
| AKNA |
INCLOSURE TYPE |
ENCAPSULATED |
| CQWD |
ZERO POWER RESISTANCE |
39.000 KILOHMS |
| CRQJ |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP |
-10.0 TO 10.0 |
| STYL |
STYLE DESIGNATOR |
15 ROD |
| TEST |
TEST DATA DOCUMENT |
80063-A3013016 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| TTQY |
TERMINAL TYPE AND QUANTITY |
2 WIRE LEAD |